Skyway SKS2GPK217 or 317
Page 2 of 2
2' x 2' Recessed Fluorescent,
LER = FP - 58.1 IW - 31.7 BF - 0.93 Comparative yearly lighting energy cost per
1000 lumens = $4.13
Report Number: G2008293
Catalog Number: SKS2GPK217UNVHI
Lamps: (2) F17T8/TL835/PLUS/ALTO
Luminaire: Skyway Recessed 2' x 2' fixture prismatic acrylic lens assembly.
Ballast:
Report is based on 1400 Lumens per lamp. Efficiency: 70.7%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.3 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 21.600 |
| 21.600 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 78 | 75 | 72 | 70 | 68 | 66 | 67 | 66 | 64 |
02 | 71 | 66 | 61 | 62 | 59 | 56 | 60 | 57 | 54 |
03 | 65 | 59 | 53 | 55 | 51 | 48 | 53 | 50 | 47 |
04 | 60 | 52 | 47 | 50 | 45 | 41 | 48 | 44 | 41 |
05 | 56 | 47 | 41 | 45 | 40 | 36 | 44 | 39 | 36 |
06 | 52 | 43 | 37 | 41 | 36 | 32 | 40 | 35 | 32 |
07 | 48 | 39 | 33 | 37 | 32 | 29 | 36 | 32 | 28 |
08 | 45 | 36 | 30 | 34 | 29 | 26 | 33 | 29 | 26 |
09 | 42 | 33 | 27 | 32 | 27 | 23 | 31 | 26 | 23 |
10 | 39 | 30 | 25 | 29 | 25 | 21 | 29 | 24 | 21 |
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 845 | 845 | 845 |
|
5 | 839 | 838 | 839 | 80 |
15 | 796 | 797 | 801 | 225 |
25 | 714 | 727 | 752 | 337 |
35 | 602 | 648 | 695 | 405 |
45 | 459 | 477 | 474 | 367 |
55 | 297 | 308 | 287 | 270 |
65 | 171 | 175 | 162 | 175 |
75 | 89 | 86 | 79 | 94 |
85 | 21 | 24 | 17 | 26 |
90 | 7 | 7 | 3 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
642 | 22.9 | 32.4 | |
1047 | 37.4 | 52.9 | |
1684 | 60.1 | 85.1 | |
1979 | 70.7 | 100.0 | |
0000 | 0.0 | 000.0 | |
1979 | 70.7 | 100.0 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 2156. | 2240. | 2226. |
55 | 1720. | 1783. | 1662. |
65 | 1344. | 1375. | 1273. |
75 | 1142. | 1103. | 1014. |
85 | 800. | 914. | 648. |
LER = FP - 46.8 IW - 46.6 BF - 0.93 Comparative yearly lighting energy cost per
1000 lumens = $5.13
Report Number: G2008296
Catalog Number: SKS2GPK317UNVH3
Lamps: (3) F217T8.TL835/PLUS/ALTO
Luminaire: Skyway Recessed 2' x 2' fixture prismatic acrylic lens assembly.
Ballast:
Report is based on 1400 Lumens per lamp. Efficiency: 72.9%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.1 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 21.600 |
| 21.600 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 80 | 77 | 74 | 72 | 70 | 68 | 69 | 68 | 66 |
02 | 74 | 68 | 64 | 64 | 61 | 58 | 62 | 59 | 56 |
03 | 68 | 61 | 55 | 57 | 53 | 49 | 55 | 52 | 49 |
04 | 62 | 54 | 48 | 51 | 47 | 43 | 50 | 46 | 42 |
05 | 58 | 49 | 43 | 47 | 42 | 38 | 45 | 41 | 37 |
06 | 53 | 44 | 38 | 42 | 37 | 33 | 41 | 37 | 33 |
07 | 50 | 40 | 34 | 39 | 34 | 30 | 38 | 33 | 30 |
08 | 46 | 37 | 31 | 36 | 31 | 27 | 35 | 30 | 27 |
09 | 44 | 34 | 29 | 33 | 28 | 24 | 32 | 28 | 24 |
10 | 41 | 32 | 26 | 31 | 26 | 22 | 30 | 25 | 22 |
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1391 | 1391 | 1391 |
|
5 | 1384 | 1378 | 1381 | 131 |
15 | 1312 | 1309 | 1315 | 370 |
25 | 1175 | 1172 | 1166 | 539 |
35 | 984 | 952 | 956 | 602 |
45 | 720 | 714 | 732 | 553 |
55 | 447 | 475 | 435 | 412 |
65 | 260 | 274 | 249 | 269 |
75 | 140 | 131 | 125 | 145 |
85 | 33 | 35 | 28 | 39 |
90 | 12 | 13 | 5 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
1040 | 24.8 | 34.0 | |
1642 | 39.1 | 53.7 | |
2607 | 62.1 | 85.2 | |
3060 | 72.9 | 100.0 | |
0000 | 0.0 | 000.0 | |
3060 | 72.9 | 100.0 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 3382. | 3353. | 3438. |
55 | 2588. | 2750. | 2519. |
65 | 2043. | 2153. | 1957. |
75 | 1796. | 1681. | 1604. |
85 | 1257. | 1334. | 1067. |
Ordering Information
Explanation of Catalog Number. Example: SKS2GPK217UNVHI
2
P
K
17
Skyway
Recessed
Fluorescent
SKSY
NK
Body Style: | Fixture | Ceiling Type: | Side Lens: | Center Lens: | Lamp | Lamp: | Voltage: |
|
|
|
|
|
|
|
|
| Options: | ||||||||||
S = Static | Width | G = Standard | P= Frost White | K= Pattern 19 | Quantity | (By Others) | 120, 277 or |
|
|
| Add appropriate | ||
A = Air |
| Grid | Acrylic Lens | .156 Virgin | 2=2 Lamp | 17 =T8 17W |
|
|
| suffix to catalog | |||
|
| T = Slot Grid |
| Acyrlic Lens | 3=3 Lamp | (Nominal 24") |
|
|
|
|
| no., ie: (A) | |
|
|
|
|
|
|
| Ballast Type: |
| Ballast | ||||
Standard Skyway |
|
|
|
|
|
|
|
| <20THD | <10THD | |||
|
|
|
|
|
|
|
| Factor | |||||
|
|
|
|
|
|
| 1 or 2 Lamp Elec. T8 | SO* | HI* | 0.88 | |||
For NYC Code – I.B.E.W. Manufactured |
|
|
|
|
| O3* | H3* | 0.88 | |||||
|
|
|
|
| Advance Optanium |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| ||
For NYC Code – Local 3 Manufactured |
|
|
|
|
| 1 or 2 Lamp Elec. T8 | – | C5* | 0.80 | ||||
|
|
|
|
| 1 - 3 Lamp Elec. T8 | – | C6* | 0.81 | |||||
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
| LOL Dimming T8 | PS* | – |
| |||
|
|
|
|
|
|
| *Instant Start Standard |
|
|
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Drywall Kit: Order Catalog Number: FK92X2.
Electrical Wiring Options: Consult factory.For motion or light sensor: See Folio
Performance: In an installation of 2 lamp 17W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .75. To reduce glare the average brightness at 65° shall not exceed 1375 candelas per square meter. To control veiling reflections, luminaire output in the
Air Handling: (SKA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provid- ed through the lamp compartment through fixture body ends.
Materials: Chassis parts are
Finish: Chassis
Other dimming options. Consult factory.
NOTE:
For T8 UNV, you must use HI OR H3 Ballast Code.
Specifications (continuned)Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information Type:
For Factory Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
www.lightolier.com © 2009 a Philips Group | Section 5/Folio |
Lightolier is a Philips group brand