Lightolier SKS2GPK224 Ordering Information, Page 2 of, Job Information Type, Skyway SKS2GPK214 or

Models: SKS2GPK214 SKS2GPK224

1 2
Download 2 pages 55.73 Kb
Page 2
Image 2
Page 2 of 2

Skyway SKS2GPK214 or 224

Page 2 of 2

2' x 2' Recessed Fluorescent, Tri-Lens Frame Static or Air Supply/Return, 2 Lamp T5 or T5HO

Model No. SKS2GPK214UNVPG

LER = FP - 56.4 IW - 32.5 BF - 1.05 Comparative yearly lighting energy cost per

1000 lumens = $4.25

Report Number: G2008325

Catalog Number: SKS2GPK214UNVPG

Lamps: (2) F14T5/835/ALTO

Luminaire: Skyway Recessed 2' x 2' fixture prismatic acrylic lens assembly.

Ballast: ICN-2S28-SC

Report is based on 1200 Lumens per lamp. Efficiency: 72.8%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.3

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

21.600

 

21.600

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

80

77

74

72

70

68

69

68

66

02

73

68

63

64

60

57

62

59

56

03

67

60

55

57

53

49

55

51

48

04

62

54

48

51

46

43

50

45

42

05

57

49

42

46

41

37

45

40

37

06

53

44

38

42

37

33

41

36

33

07

49

40

34

38

33

29

37

33

29

08

46

37

31

35

30

26

34

30

26

09

43

34

28

33

28

24

32

27

24

10

41

31

26

3O

25

22

30

25

22

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

748

748

748

 

5

743

742

742

71

15

704

705

705

199

25

633

643

669

299

35

533

578

612

358

45

405

420

414

323

55

263

269

251

237

65

151

153

142

154

75

79

76

68

82

85

19

18

15

23

90

5

6

2

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

568

23.7

32.6

00-040

927

38.6

53.1

00-060

1487

62.0

85.2

00-090

1746

72.8

100.0

90-180

0000

0.0

000.0

00-180

1746

72.8

100.0

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

1902.

1973.

1944.

55

1523.

1558.

1453.

65

1187.

1202.

1116.

75

1014.

975.

873.

85

724.

686.

572.

Model No. SKS2GPK224UNVPG

LER = FP - 52.4 IW - 51.3 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $4.58

Report Number: G2008179

Catalog Number: SKS2GPK224UNVPG

Lamps: (2) F24T5HO

Luminaire: Skyway Recessed 2' x 2' fixture prismatic acrylic lens assembly.

Ballast: ICN-2S24

Report is based on 1800 Lumens per lamp. Efficiency: 74.6%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.3

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

21.600

 

21.600

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

82

79

76

74

72

70

71

69

68

02

75

70

65

66

62

59

63

60

58

03

69

62

56

59

54

51

57

53

50

04

64

55

49

53

48

44

51

47

43

05

59

50

44

48

42

38

46

42

38

06

55

45

39

43

38

34

42

37

34

07

51

41

35

40

34

30

39

34

30

08

47

38

32

36

31

27

35

31

27

09

44

35

29

34

28

25

33

28

25

10

42

32

27

31

26

23

30

26

23

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

1153

1153

1153

 

5

1145

1145

1146

109

15

1087

1094

1101

309

25

977

1007

1055

467

35

822

901

954

557

45

625

648

639

497

55

399

412

384

362

65

224

231

215

231

75

113

113

103

122

85

26

24

21

21

90

0

0

0

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

885

24.6

32.9

00-040

1442

40.0

53.7

00-060

2301

63.9

85.7

00-090

2685

74.6

100.0

90-180

0000

0.0

000.0

00-180

2685

74.6

100.0

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

2935.

3043.

3001.

55

2310.

2385.

2223.

65

1760.

1815.

1689.

75

1450.

1450.

1322.

85

991.

914.

800.

Ordering Information

Explanation of Catalog Number. Example: SKS2GPK214UNVPG

2

P

K

2

Skyway

Body Style:

Fixture

Ceiling Type:

Side Lens:

Center Lens:

Lamp

Lamp:

Recessed

S = Static

Width

G = Standard

P= Frost White

K= Pattern 19

Quantity

(By Others)

Fluorescent

A = Air

 

Grid

Acrylic Lens

.156 Virgin

2=2 Lamp

14=T5 14W

 

 

 

 

T = Slot Grid

 

Acyrlic Lens

 

24=T5HO 24W

 

 

 

 

 

 

 

 

(Nominal 24")

SK

Standard Skyway

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SY

 

For NYC Code – I.B.E.W. Manufactured

 

 

 

 

 

 

 

 

 

 

 

 

 

NK

For NYC Code – Local 3 Manufactured

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options/Accessories

Voltage:

 

 

 

 

 

 

 

Options:

120, 277 or

 

 

Add appropriate

UNV=120-277

 

 

suffix to catalog

 

 

 

 

no., ie: (A)

Ballast Type:

 

 

 

 

<20THD <10THD

2 Lamp Elec. T5

 

PG ††

(14 Watt)

 

 

PG ††

2 Lamp Elec. T5HO

 

(24 Watt)

 

 

 

 

††Program Rapid Start (UNV only)

Fusing: Internal fast blow fusing: SUFFIX: A.

Internal slow blow fusing: SUFFIX: C.

Drywall Kit: Order Catalog Number: FK92X2.

Electrical Wiring Options: Consult factory.

For motion or light sensor: See Folio OA20-10 and OA20-30.

Specifications

Performance: In an installation of 2 lamp 14W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .77. To reduce glare the average brightness at 65° shall not exceed 1202 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 67.4%.

Air Handling: (SKA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provid- ed through the lamp compartment through fixture body ends.

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing has side rails hemmed over and housing ends turned-in for safe handling.

Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating. Reflectors- 95% reflective white powder coated.

Specifications (continuned)

Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly.

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Job Information Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

www.lightolier.com © 2009 a Philips Group

Section 5/Folio MA12-12

Lightolier is a Philips group brand

Page 2
Image 2
Lightolier SKS2GPK224 Ordering Information, Page 2 of, Job Information Type, Skyway SKS2GPK214 or, Options/Accessories