Lightolier SLB1SFSVA232 Page 2 of, Photometry, Ordering Information, Options & Accessories, Type

Models: SLB1SFSVA232

1 2
Download 2 pages 7.06 Kb
Page 2
Image 2
Page 2 of 2
Section 3A/Folio H70-10

SLB Surface Box 1' x 4' Fluorescent SLB1SFSVA232

Page 2 of 2

Flat Steel or Regressed Aluminum Frame, 2 Lamp T8 or T12

Photometry

Model No. SLB1SFSVA232120SO

SLB2SFSVA232120SO

2850

coefficients of utilization — zonal cavity method

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

 

1

62

60

58

56

55

54

54

53

52

ratio

2

58

54

51

51

48

46

49

47

45

3

53

48

45

46

43

40

45

42

40

 

cavity

4

49

44

39

42

38

36

40

37

35

5

46

39

35

37

34

31

36

33

31

room

6

42

36

31

34

30

27

33

30

27

7

39

32

28

31

27

24

30

27

24

 

8

36

29

25

28

24

21

27

24

21

 

9

33

26

22

25

21

19

25

21

19

 

10

31

24

20

23

19

17

23

19

17

Ordering Information

Explanation of Catalog Number. Example: SLB1SFSVA232120SO

SL

 

B

 

1

 

S

 

 

 

 

 

 

 

 

 

 

VA

2

Body Style:

Fixture

Ceiling Type:

 

Lamp

Lamp/Fixture

Voltage:

 

Options:

Surface Box

Width

S = Surface

Lens

Quantity:

Length:

120 or 277

 

Add appropriate

 

 

Lens

2 = 2 Lamp

32 = T8

 

 

suffix to catalog

SLB Surface:

 

Frame:

Shielding Type:

 

34 = T12

Ballast Type:

no, ie: (GLR)

 

FS = Flush full-

VA = Pattern 12

 

(Nominal 48")

 

Lens Frame

 

size steel

lens, .095"

 

 

1 & 2 Lamp Mag. T12 LE

 

Surface

 

 

 

<20THD <10THD

 

frame

nominal pris-

 

 

Fluorescent

 

RA = Regressed

matic lens

 

 

1 & 2 Lamp Elec. T8

SO*

HI*

 

 

flush full-

(standard).

 

 

LOL Dimming T8

PS*

 

 

size

see options

 

 

*Instant Start Standard

 

 

 

aluminum

and consult

 

 

 

 

 

 

 

Other dimming options. Consult factory.

 

 

frame

factory.

 

 

 

 

 

 

 

 

 

Options & Accessories

Fusing: Internal fast-blow fusing. Suffix: GLR.

Internal slow-blow fusing. Suffix: GMF.

Electrical/Wiring Options: Consult factory.

Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture.

Suffix: R. One per ballast, Suffix: B.

Stem and Canopy Sets: Suspends fixture 6", 12" 18" or 24" from surface. (Four

per fixture is recommended. Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24").

Specifications

Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .60. To prevent glare the average brightness at 65° shall not exceed 2037 candelas per square meter. To control veiling reflections, luminaire output in the 30–90° zone shall be not less than 65%.

Materials: Chassis parts are die-formed 20 gauge cold rolled steel.

Finish: White baked polyester powder coat.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and C-UL.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. Copyright 2002 Lightolier