| Lighting Systems | ||||||||||
1BHFPG |
|
|
|
|
| -JHIU51FS'PPU /PNJOBM 4FDUJPO | ||||||||||
Performance |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
CANDLEPOWER CURVE | CANDLEPOWER |
|
|
| COEFFICIENTS OF UTILIZATION |
| ||||||||||
ZONE | 0 | 22 | 45 | 67 | 90 |
| % EFFECTIVE CEILING CAVITY REFLECTANCE | |||||||||
|
|
|
|
|
|
|
|
|
| |||||||
|
| CANDELAS |
|
|
|
| 80% |
|
| 70% |
|
| 50% |
| ||
DEG. |
|
|
|
|
|
|
| WALL R EFLE CTAN CE |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
180 | 1333 | 1333 | 1333 | 1333 | 1333 |
| 70 | 50 | 30 | 70 | 50 | 30 | 50 | 30 | 10 | |
175 | 1338 | 1345 | 1351 | 1355 | 1366 | 0 | 90 | 90 | 90 | 77 | 77 | 77 | 52 | 52 | 52 | |
165 | 1287 | 1358 | 1468 | 1555 | 1598 | 1 | 82 | 78 | 75 | 70 | 67 | 62 | 46 | 44 | 43 | |
2 | 74 | 68 | 63 | 63 | 58 | 50 | 40 | 37 | 35 | |||||||
155 | 1196 | 1355 | 1604 | 1789 | 1874 | |||||||||||
3 | 68 | 60 | 43 | 58 | 51 | 42 | 35 | 32 | 29 | |||||||
145 | 1052 | 1323 | 1722 | 2035 | 2167 | 4 | 62 | 43 | 46 | 53 | 45 | 35 | 31 | 28 | 25 | |
135 | 874 | 1261 | 1825 | 2292 | 2500 | 5 | 46 | 46 | 39 | 48 | 40 | 30 | 27 | 24 | 21 | |
6 | 52 | 41 | 34 | 44 | 36 | 26 | 25 | 21 | 18 | |||||||
125 | 660 | 1169 | 1941 | 2653 | 2934 | 7 | 48 | 37 | 30 | 40 | 32 | 22 | 22 | 18 | 16 | |
115 | 435 | 1069 | 2154 | 2831 | 3019 | 8 | 44 | 33 | 27 | 37 | 29 | 19 | 20 | 16 | 14 | |
9 | 41 | 30 | 24 | 65 | 26 | 17 | 18 | 14 | 12 | |||||||
105 | 215 | 1057 | 1929 | 2078 | 2057 | 10 | 38 | 27 | 21 | 32 | 24 | 15 | 16 | 13 | 11 | |
95 | 42 | 556 | 517 | 535 | 468 |
|
| 20% FLOOR CAVITY REFLECTANCE |
| |||||||
90 | 0 | 0 | 0 | 0 | 0 |
|
|
|
|
|
|
|
|
|
|
| DISTRIBUTION |
|
|
| ||
REPORT NO.: ITL53330 |
| Zone Lumens % Lamp | % Luminaire | |||
0 | 0.0 | 0.0 | ||||
LAMPS: | ||||||
9946 | 94.5 | 100.0 | ||||
LUMENS: 5000 | ||||||
EFFICIENCY: 94.5% | 9946 | 94.5 | 100.0 | |||
CAT NO.: S254C04WH |
|
|
|
|
|
Fixture Lengths & Mounting Locations
|
|
|
|
|
|
|
| 4' |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| 4' |
|
|
|
|
|
|
|
|
| Notes: Suspended luminaires can be continuously | |||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| row mounted longer than |
|
|
|
|
|
|
|
|
| 8' |
|
|
|
| capacity of power cords cannot be exceeded. | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
| 8' |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
12'
17'
|
|
|
|
|
|
| 21' |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 12' |
|
|
|
|
|
|
|
|
| 8' 6" (259.08cm) |
|
|
|
|
Mounting Accessories
Power Feed Cable End Set | Stem End Set | Intermediate Cable | Intermediate Stem | Intermediate Cable/Cord |
Distance is from the ceiling | Distance is from the ceiling | Distance is from the ceiling | Distance is from the ceiling | Distance is from the ceiling |
line to the top of the lumi- | line to the top of the lumi- | line to the top of the lumi- | line to the top of the lumi- | line to the top of the lumi- |
naire housing. | naire housing. | naire housing. | naire housing. | naire housing. |
36” (91.44cm) Platinum: SECO36SC | 30” (76.20cm) Platinum: SESO3ØSC | 36” (91.44cm) Platinum: SICO36SC | 30” (76.20cm) Platinum: SISO3ØSC | 36” (91.44cm) Platinum: SIPO36SC |
36” (91.44cm) White: SECO36WH | 30” (76.20cm) White: SESO3ØWH | 36” (91.44cm) White: SICO36WH | 30” (76.20cm) White: SISO3ØWH | 36” (91.44cm) White: SIPO36WH |
Job Information | Type: |
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #