![Lighting Systems SORA-4](/images/new-backgrounds/41923/419231x1.webp)
Lighting Systems SORA-4
1BHFPG | -JHIU51FS'PPU /PNJOBM 4FDUJPO |
8.00” (20.32cm)
2.40”
(6.10cm)
1 | 2 | 3 |
Ordering Information
| Family |
Body | S |
|
|
| Family |
Suspension | S |
|
|
Complete Ordering Instructions below.
Lamps
2
2 = 2 Lamps Per
Item
E = End Set
I = Intermediate
Wattage
28 = 28 Watt
54 = 54 Watt
Suspension
CO = Cable
SO = Stem
PO = Power Feed*
Style
CO
CO = Suspended
without
Wings
Length
30 = 30” (76.20cm) Stem
36 = 36” (91.44cm) Cable
Length
4 = 4 Foot
Nominal
8 = 8 Foot
Nominal
12 = 12 Foot
Nominal
Finish
SC = Platinum WH = White
Finish
SC = Platinum
WH = White
* Intermediate only.
Features
1.Housing: Aluminum extruded upto
2.Lamp: T5 linear fluorescent, 28 or 54 watt. (by others).
3.Reflector:
Electrical
Ballast is electronic, low harmonic distortion, high power and ballast factor, uni- versal voltage with two conductors and a ground. Mark X dimming (no extra control wire required) is available. EM battery pack not available. Modules can be continuously wired row mounted, but cannot exceed amperage limits of electrical supply cords. Cable suspended fixtures have 18/3 SJT cord, stem products have three 18 gauge wires provided in stem, and both versions must be hard wired. Factory installed ballast disconnect allows the ballast to be disconnected from and reconnected to incoming power under load without turning the entire circuit off.
Mounting
Cable mounting utilize 1/16” (0.16cm) diameter SSTL aircraft cable, and are continuously adjustable via a cable gripper. Stem mountings utilize 1/8 IP stems (three wires only) with ball swivel mounting at ceiling line. Stems cannot be cut in field and should be ordered to required length.
Finish
Powder coated Steelcase Platinum or White baked enamel.
Custom colors available, consult factory.
Labels
UL (1598), cUL and I.B.E.W.
Ordering Instructions
Individual fixtures:
1.Order number of Modules required.
2.Order one End Set per module.
Continuos Rows:
1.Determine run length.
2.Order the appropriate number of Modules to complete the run.
3.Order one End Set per run.
4.Order one Intermediate suspension per Module minus one per run.
5.For runs that exceed amperage limits, order the appropriate number of Intermediate suspension Power (for cable suspended units only).
Job Information | Type: |
Job Name:
Cat. No.:
Lamp(s):
Notes:
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #