Photometry

REPORT NO: G89007

CATALOG NO: SS4S132HPF120SO

LAMP TYPE: 1F32 T8

LUMENS PER LAMP: 2850 TOTAL

EFFICIENCY: 89.5%

CIE TYPE: Semi-Direct

SPACING CRITERIA: 1.6

SHIELDING ANGLE: 180

4-1/4" Wide, 1-5/8" Deep, 24", 36", 48", 69", 93" Length, Individual or Tandem, 1 Lamp T8 or T12

Model No. SS4S132HPF120SO

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

 

1

89

84

79

71

68

64

64

61

58

ratio

2

80

71

64

60

55

51

54

50

46

3

72

62

53

52

46

41

47

42

38

cavity

4

65

54

45

46

39

34

41

36

31

5

59

47

39

40

34

28

36

30

26

room

6

54

42

33

36

29

24

32

26

22

7

50

37

29

32

25

21

29

23

19

 

 

8

46

33

25

29

22

18

26

20

16

 

9

43

30

22

26

20

15

23

18

14

 

10

40

27

20

24

18

13

21

16

12

Ordering Information

Explanation of Catalog Number. Example: SS4S132HPF120SOGLR

SS

 

 

 

 

 

 

 

1

 

 

 

 

HPF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Staggered Strip:

Fixture Length:

Lamp Configuration:

Lamp Quantity

4-1/4" wide

2=24"

S=Standard

 

channel

3=36"

T= 3' or 4' Lamps

 

 

4=48"

in Tandem

 

 

6=69"

(for 6' or 8' Units)

 

 

8=93"

 

 

†No Product Change. New Catalog Number Designation.

Options/Accessories

Fusing: Internal fast-blow fusing. Suffix: GLR.

Internal slow-blow fusing. Suffix: GMF.

Electrical Wiring Options: Consult factory.

Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture.

Suffix: R. One per ballast. Suffix: B.

Stem and Canopy Sets: Suspends fixture 6', 12', 18' or 24' from surface.

Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"),

ASC24 CSP (24").

Lamps:

(By Others)

17=17 watt (T8)

20=20 watt (T12) (Nominal 24")

25=25 watt (T8)

30=30 watt (T12) (Nominal 36")

32=32 watt (T8)

34=34 watt (T12) (Nominal 48")

(One lamp in tandem

for 69" and 93" fixtures)

Ballast Type:

HPF=High Power

Factor

Voltage:

 

Options:

120 or 277

 

Add appropriate

Ballast:

suffix to catalog

no., ie: (GLR)

1 or 2 Lamp Mag. T12

LE

 

Standard Electro-

 

 

Magnetic (20 or

P

 

30 watts only)

 

 

<20THD

<10THD

1 or 2 Lamp Elec. (T8)

SO*

HI*

LOL Dimming (T8)

PS

*Instant Start Standard

Other dimming options. Consult factory.

Specifications

Materials: Chassis parts are die formed heavy duty code gauge cold rolled steel.

Ballast cover–code gauge cold rolled steel, secured by plated quarter-turn latches.

Finish: Chassis exterior–baked white polyester enamel, minimum reflectance 86%.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

Job Information

Type:

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2003 Genlyte Thomas Group LLC (Lightolier Division) A0303

Section3A/Folio H130-11

Page 2
Image 2
Lightolier SS 1 LAMP Page 2 of, Photometry, Ordering Information, Options/Accessories, Specifications, A/Folio H130-11