Lightolier V611 Installation Of Pre-Wiredcalculite Frame-In-Kits, B. Adjust Mounting Frame

Models: V611

1 2
Download 2 pages 31.94 Kb
Page 2
Image 2
INSTALLATION OF PRE-WIRED CALCULITE FRAME-IN-KITS

nuea I

Page 2 of 2

INSTALLATION OF PRE-WIRED CALCULITE FRAME-IN-KITS

A-LAMP WALL WASHER/DOWNLIGHT (Cent’d)

B. ADJUST MOUNTING FRAME

For both plaster or other dry ceiling installation, MOUNTING FRAME must be set so that the bottom edge is flush with the finished ceiling, as shown on Fig. 6.

NOTE: 1. To insure

proper installation, the

MOUNTING FRAME

FIG. 6

must always”

be” secure to structural

ceiling members.

2.Final vertical adjustment can be made by means of MOUNTING BRACKET SCREWS (Fig. 2) on inside of

MOUNTING FRAME.

c.ADJUST SOCKET HOUSING

Engage SPRING to SLOTS for desired lamp/wattage position (see label on inside and outside of neck of REFLECTOFUHOUSING as shown on Fig. 7).

ADJUSTABLE SOCKET

HOUSING

SLOT

NOTE: To remove REFLE(70R/HOUSING for inspection and maintenance, push RETAINING SPRINGS outward and detach REFLECTOR/HOUSING from MOUNTING FRAME (See Fig. 1).

To insure neat installation, do not remove CARDBOARD PAINT SHIELD (provided) in MOUNTING FRAME (Fig. 1). The SHIELD will protect the inside of REFLECTOR/HOUSING from paint, pIaster and dust. Remove it only after construction is completed.

/RETAINING SPRINGS

FIG. 7

D. CARE AND MAINTENANCE OF “Al-ZAK”

REFLECTOR

If handling of reflectors with anodized or Alzak finish is required, the use of clean white or plastic film gloves recommended to avoid fingerprints.

Anodized or Alzak surfaces can be cleaned by the following methods:

1.Wipe off with a soft, clean, dry, lint-free cloth.

2.Wipe off with a soft clean cloth dampened in mild detergent solution. Rinse, then wipe dry with lint-free cloth or paper towel.

3.Wipe off with a clean cloth dampened with a solution of wetting agent and water (such as 2 oz. per gallon “Pluronic L62-LF” by Wyandotte Products) or a liquid wax such as Glass Wax@. Then wipe dry. Avoid gritty cleaning agents.

Page 2
Image 2
Lightolier V611 instruction sheet Installation Of Pre-Wiredcalculite Frame-In-Kits, A-LAMPWALL WASHER/DOWNLIGHT Cent’d