| VP PARABOLIC VPA2G12PP317 |
Page 2 of 2 | 2'x2' RECESSED FLUORESCENT, 4" DEEP, 12 CELL (3x4) PARABOLIC LOUVER |
| STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED) |
PHOTOMETRY
| LER = FP - 49.0 | IW - 47.0 | BF - 0.90 |
|
|
|
|
|
|
|
|
| ||||||||
MODEL NO. VPA2G12PP317SO Comparative yearly lighting energy cost per 1000 lumens = $4.89 |
|
|
| |||||||||||||||||
|
| coefficients of utilization — zonal cavity method | (effective floor cavity reflectance 0.20) |
| ||||||||||||||||
|
|
| RF |
|
| 20 |
|
|
|
|
| 20 |
|
|
|
|
| 20 |
| |
|
|
| RC |
|
| 80 |
|
|
|
|
| 50 |
|
|
|
|
| 30 |
| |
|
|
| RW |
| 70 | 50 |
| 30 |
| 50 |
| 30 |
| 10 |
|
| 50 | 30 | 10 | |
|
|
| 1 |
| 70 | 68 |
| 67 |
| 64 |
| 63 |
| 62 |
|
| 62 | 61 | 60 | |
|
| ratio | 2 |
| 66 | 63 |
| 60 |
| 60 |
| 58 |
| 56 |
|
| 58 | 56 | 55 | |
|
| 3 |
| 62 | 58 |
| 55 |
| 55 |
| 53 |
| 51 |
|
| 54 | 52 | 50 | ||
|
| cavity | 4 |
| 59 | 53 |
| 49 |
| 51 |
| 48 |
| 46 |
|
| 50 | 47 | 45 | |
|
| 5 |
| 55 | 49 |
| 45 |
| 47 |
| 44 |
| 41 |
|
| 46 | 43 | 41 | ||
|
| room | 6 |
| 51 | 45 |
| 41 |
| 44 |
| 40 |
| 37 |
|
| 43 | 39 | 37 | |
|
| 7 |
| 48 | 41 |
| 37 |
| 40 |
| 36 |
| 34 |
|
| 39 | 36 | 33 | ||
|
|
| 8 |
| 44 | 37 |
| 33 |
| 36 |
| 33 |
| 30 |
|
| 36 | 32 | 30 | |
|
|
| 9 |
| 41 | 34 |
| 29 |
| 33 |
| 29 |
| 26 |
|
| 32 | 29 | 26 | |
|
|
| 10 |
| 38 | 31 |
| 26 |
| 30 |
| 26 |
| 23 |
|
| 29 | 26 | 23 | |
|
| visual comfort probability | (rated lumens per lamp 3150.) |
|
|
|
|
|
| |||||||||||
|
|
| room size |
|
|
|
|
| ceiling height |
|
|
|
|
| ceiling height |
|
| |||
|
| W |
|
| L |
|
|
| 8.5 | 10.0 | 13.0 | 16.0 |
|
|
| 8.5 | 10.0 | 13.0 |
| 16.0 |
| 20 |
|
| 20 |
|
|
| 89 | 93 | 92 | 83 |
|
|
| 98 | 98 | 98 |
| 93 | |
| 20 |
|
| 30 |
|
|
| 89 | 93 | 92 | 83 |
|
|
| 98 | 99 | 98 |
| 94 | |
| 20 |
|
| 40 |
|
|
| 89 | 93 | 92 | 84 |
|
|
| 98 | 99 | 98 |
| 94 | |
|
| 20 |
|
| 60 |
|
|
| 90 | 94 | 92 | 84 |
|
|
| 98 | 99 | 98 |
| 94 |
| 30 |
|
| 20 |
|
|
| 89 | 93 | 92 | 86 |
|
|
| 98 | 99 | 98 |
| 94 | |
| 30 |
|
| 30 |
|
|
| 90 | 94 | 92 | 87 |
|
|
| 98 | 99 | 98 |
| 94 | |
| 30 |
|
| 40 |
|
|
| 90 | 94 | 92 | 87 |
|
|
| 98 | 99 | 98 |
| 94 | |
| 30 |
|
| 60 |
|
|
| 90 | 94 | 92 | 87 |
|
|
| 98 | 99 | 98 |
| 94 | |
|
| 30 |
|
| 80 |
| lengthwise |
| 90 | 94 | 92 | 87 |
|
| crosswise | 98 | 99 | 98 |
| 95 |
| 40 |
|
| 40 |
|
| 90 | 94 | 92 | 87 |
|
| 98 | 99 | 98 |
| 94 | |||
| 40 |
|
| 20 |
|
|
| 89 | 93 | 92 | 86 |
|
|
| 98 | 99 | 98 |
| 94 | |
| 40 |
|
| 30 |
| luminaries |
| 90 | 94 | 92 | 87 |
|
| luminaries | 98 | 99 | 98 |
| 94 | |
| 40 |
|
| 60 |
|
| 90 | 94 | 93 | 87 |
|
| 98 | 99 | 98 |
| 95 | |||
| 40 |
|
| 80 |
|
|
| 90 | 94 | 93 | 87 |
|
|
| 98 | 99 | 98 |
| 95 | |
|
| 40 |
|
| 100 |
|
|
| 90 | 94 | 93 | 87 |
|
|
| 98 | 99 | 98 |
| 95 |
| 60 |
|
| 30 |
|
|
| 90 | 94 | 92 | 87 |
|
|
| 98 | 99 | 98 |
| 94 | |
| 60 |
|
| 40 |
|
|
| 90 | 94 | 93 | 87 |
|
|
| 98 | 99 | 98 |
| 95 | |
| 60 |
|
| 60 |
|
|
| 90 | 94 | 93 | 87 |
|
|
| 98 | 99 | 98 |
| 95 | |
|
|
|
|
|
|
|
|
|
| |||||||||||
| 60 |
|
| 80 |
|
|
| 90 | 94 | 93 | 87 |
|
|
| 98 | 99 | 98 |
| 95 | |
|
| 60 |
|
| 100 |
|
|
| 90 | 94 | 93 | 87 |
|
|
| 98 | 99 | 98 |
| 95 |
| 100 |
|
| 40 |
|
|
| 90 | 94 | 93 | 87 |
|
|
| 98 | 99 | 98 |
| 95 | |
| 100 |
|
| 60 |
|
|
| 90 | 94 | 93 | 87 |
|
|
| 98 | 99 | 98 |
| 95 | |
| 100 |
|
| 80 |
|
|
| 90 | 94 | 93 | 87 |
|
|
| 98 | 99 | 98 |
| 95 | |
|
| 100 |
|
| 100 |
|
|
| 90 | 94 | 93 | 88 |
|
|
| 98 | 99 | 98 |
| 95 |
ORDERING INFORMATION Explanation of Catalog Number. Example: VPA2G12PP317120SOGLR
VP
2
12
P
P
3
17
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VOLTAGE: |
|
|
|
| OPTIONS: | ||
|
|
|
|
| BODY STYLE: |
|
| CEILING TYPE: |
|
|
| LOUVER |
|
|
| LAMP |
|
|
|
|
|
|
| |||||||||
|
|
|
| A=Air Handling |
|
| G= Grid |
|
|
| FINISH*: |
|
|
| QUANTITY |
|
|
|
| 120 or 277 |
|
|
| Add appropriate | ||||||||
|
|
|
| S=Static |
|
|
|
|
| P=Low |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| suffix to catalog | ||||||
| VP: |
|
|
|
|
| F=Flanged |
|
|
| Iridescence |
|
|
|
|
|
| LAMP TYPE/ |
|
|
|
|
|
| no, ie: (GLR) | |||||||
|
|
|
| FIXTURE | NUMBER OF | DUAL “V” |
|
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
| (overlap) | Specular |
|
|
|
|
|
| BALLAST TYPE: |
| |||||||||||||||||||
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||
| 4" Deep |
|
| WIDTH | Z spline and | CELLS: |
|
| REFLECTOR |
|
|
|
| FIXTURE |
|
|
|
| <20THD | <10THD | ||||||||||||
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||
|
|
|
|
| plaster frame | (3 rows of |
|
|
|
|
|
|
|
| LENGTH: |
| 1&2 Lamp Elec. T8 |
|
| SO* | HI* | |||||||||||
| Aluminum |
|
|
|
| 4 cells) |
|
|
|
|
|
|
|
| 17=T8, 2' Lamp |
|
|
| ||||||||||||||
| Louver |
|
|
|
| T=Slot grid or |
|
|
|
|
|
|
|
|
|
|
| (Nominal 24") |
|
| O3* | H3* | ||||||||||
| For Intense |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LOL T8 Dimming |
|
| PS | – | ||||||||
| VDT Use |
|
|
|
| concealed T |
|
|
|
|
|
|
|
|
|
|
|
|
|
| *Instant Start Standard |
|
|
|
| |||||||
|
|
|
|
| (see options) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Other dimming options. Consult factory.
OPTIONS & ACCESSORIES
PLASTER FRAME: Catalog Number: PF22.
CONTINUOUS ROW INSTALLATION: For F type fixtures,
required between fixtures. Order Catalog Number: S2FCTRIM (each joint).
SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ22 S2 SPLAY TRIM.
RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture
standard. SUFFIX: RF.
ELECTRICAL WIRING OPTIONS: Consult factory.
AIR CLOSURE STRIP: SUFFIX ACS2 (factory installed).
DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio
CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: In an installation of 2 lamp 17W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .68 with a spacing to mounting ratio of 1.4 perpendicular to the lamps. To meet IES RP1 preferred requirements for VDT areas the VCP (visual comfort proba- bility) shall not be less than 90 either crosswise or lengthwise and the maximum average brightness at 55°, 65°, 75° and 85° shall not exceed 637, 32, 13 and 0 candelas per square meter respectively in the 0°, 45°, and 90° horizontal planes.
SPECIFICATIONS (continued)
AIR HANDLING: (VPA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp com- partment through fixture body ends.
MATERIALS: Chassis parts are die formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends
FINISH: Chassis
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and
Job Information |
| Type: |
Lightolier a Genlyte Thomas Company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902