| VR PARABOLIC VRA1G12LS132 |
Page 2 of 2 | 1'x4' RECESSED FLUORESCENT, 3" DEEP, 12 CELL (1 ROW) PARABOLIC LOUVER |
| STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE |
PHOTOMETRY
| LER = FP - 50.1 | IW - 30.6 |
| BF - 0.88 |
|
|
|
|
|
|
|
| |||||||
MODEL NO. VRA1G12LS132120SO Comparative yearly lighting energy cost per 1000 lumens = $4.80 |
|
|
| ||||||||||||||||
|
| coefficients of utilization — zonal cavity method |
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
| ||||||||||||
|
|
| RF |
|
| 20 |
|
|
|
| 20 |
|
|
|
|
| 20 |
| |
|
|
| RC |
|
| 80 |
|
|
|
| 50 |
|
|
|
|
| 30 |
| |
|
|
| RW |
| 70 | 50 |
| 30 |
| 50 | 30 |
| 10 |
|
| 50 | 30 | 10 | |
|
|
| 1 |
| 69 | 67 |
| 65 |
| 63 | 61 |
| 60 |
|
| 61 | 59 | 58 | |
|
| ratio | 2 |
| 64 | 61 |
| 58 |
| 58 | 55 |
| 53 |
|
| 56 | 54 | 52 | |
|
| 3 |
| 60 | 55 |
| 51 |
| 52 | 49 |
| 47 |
|
| 51 | 48 | 46 | ||
|
|
|
|
|
|
|
|
| |||||||||||
|
| cavity | 4 |
| 56 | 50 |
| 45 |
| 48 | 44 |
| 41 |
|
| 46 | 43 | 41 | |
|
| 5 |
| 51 | 45 |
| 40 |
| 43 | 39 |
| 36 |
|
| 42 | 38 | 36 | ||
|
| room | 6 |
| 47 | 40 |
| 36 |
| 39 | 35 |
| 32 |
|
| 38 | 34 | 32 | |
|
| 7 |
| 44 | 36 |
| 31 |
| 35 | 31 |
| 28 |
|
| 34 | 30 | 28 | ||
|
|
| 8 |
| 40 | 32 |
| 27 |
| 31 | 27 |
| 24 |
|
| 30 | 27 | 24 | |
|
|
| 9 |
| 37 | 29 |
| 24 |
| 28 | 23 |
| 20 |
|
| 27 | 23 | 20 | |
|
|
| 10 |
| 34 | 26 |
| 21 |
| 25 | 21 |
| 18 |
|
| 24 | 21 | 18 | |
|
| visual comfort probability |
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
| room size |
|
|
|
|
| ceiling height |
|
|
|
| ceiling height |
|
| |||
|
| W |
|
| L |
|
|
| 8.5 | 10.0 | 13.0 | 16.0 |
|
| 8.5 | 10.0 | 13.0 |
| 16.0 |
| 20 |
|
| 20 |
|
|
| 95 | 94 | 92 | 88 |
|
| 90 | 85 | 81 |
| 80 | |
| 20 |
|
| 30 |
|
|
| 96 | 94 | 93 | 90 |
|
| 90 | 88 | 82 |
| 77 | |
| 20 |
|
| 40 |
|
|
| 96 | 95 | 93 | 92 |
|
| 90 | 88 | 83 |
| 79 | |
|
| 20 |
|
| 60 |
|
|
| 96 | 95 | 94 | 92 |
|
| 90 | 88 | 84 |
| 79 |
| 30 |
|
| 20 |
|
|
| 95 | 94 | 92 | 87 |
|
| 90 | 87 | 85 |
| 82 | |
| 30 |
|
| 30 |
|
|
| 96 | 95 | 94 | 89 |
|
| 90 | 89 | 85 |
| 79 | |
| 30 |
|
| 40 |
|
|
| 96 | 95 | 94 | 91 |
|
| 90 | 88 | 86 |
| 80 | |
| 30 |
|
| 60 |
|
|
| 97 | 96 | 95 | 91 |
|
| 91 | 88 | 86 |
| 80 | |
|
| 30 |
|
| 90 |
| lengthwise |
| 97 | 96 | 95 | 91 |
| crosswise | 91 | 88 | 86 |
| 80 |
| 40 |
|
| 40 |
|
| 97 | 95 | 94 | 91 |
| 91 | 88 | 87 |
| 82 | |||
| 40 |
|
| 20 |
|
|
| 95 | 95 | 93 | 88 |
|
| 90 | 87 | 85 |
| 84 | |
| 40 |
|
| 30 |
| luminaries |
| 96 | 95 | 94 | 90 |
| luminaries | 90 | 88 | 86 |
| 82 | |
| 40 |
|
| 60 |
|
| 97 | 96 | 95 | 91 |
| 91 | 88 | 87 |
| 82 | |||
| 40 |
|
| 80 |
|
|
| 97 | 96 | 95 | 91 |
|
| 91 | 88 | 87 |
| 83 | |
|
| 40 |
|
| 100 |
|
|
| 97 | 96 | 95 | 91 |
|
| 91 | 88 | 87 |
| 83 |
| 60 |
|
| 30 |
|
|
| 96 | 95 | 94 | 91 |
|
| 91 | 88 | 86 |
| 82 | |
| 60 |
|
| 40 |
|
|
| 97 | 96 | 94 | 92 |
|
| 91 | 88 | 87 |
| 83 | |
| 60 |
|
| 60 |
|
|
| 97 | 96 | 95 | 92 |
|
| 91 | 89 | 87 |
| 83 | |
|
|
|
|
|
|
|
| ||||||||||||
| 60 |
|
| 80 |
|
|
| 97 | 96 | 95 | 92 |
|
| 91 | 89 | 87 |
| 83 | |
|
| 60 |
|
| 100 |
|
|
| 97 | 96 | 95 | 92 |
|
| 91 | 89 | 87 |
| 83 |
| 100 |
|
| 40 |
|
|
| 97 | 95 | 94 | 92 |
|
| 91 | 88 | 87 |
| 83 | |
| 100 |
|
| 60 |
|
|
| 97 | 96 | 95 | 92 |
|
| 91 | 89 | 87 |
| 83 | |
| 100 |
|
| 80 |
|
|
| 97 | 96 | 95 | 92 |
|
| 91 | 89 | 87 |
| 83 | |
|
| 100 |
|
| 100 |
|
|
| 97 | 96 | 95 | 92 |
|
| 91 | 89 | 87 |
| 83 |
ORDERING INFORMATION
Explanation of Catalog Number. Example:VRA1G12LS132120SOGLR
VR
1
12
S
1
|
|
|
|
|
| BODY STYLE: |
|
BLANK = Standard |
| ||||||
| A=Air Handling |
| |||||
N = NYC Code |
|
| |||||
| S=Static |
| |||||
|
|
|
|
|
|
| |
|
|
|
| VR: | FIXTURE | ||
|
|
|
| 3" Deep | WIDTH | ||
|
|
|
| Pre- |
|
| |
|
|
|
| anodized |
|
| |
|
|
|
| Aluminum |
|
| |
|
|
|
| Louver |
|
| |
|
|
|
| for normal |
|
| |
|
|
|
| VDT use |
|
|
CEILING TYPE: G= Grid
Z spline and plaster frame
T=Slot grid or
NUMBER OF
CELLS:
1 row of
12 cells
LOUVER
FINISH: L=Low
Iridescence
(standard)
P=Low
iridescence
specular
|
|
|
|
|
|
|
|
|
|
| LAMP |
|
|
| |
|
|
| QUANTITY |
|
|
| |
|
|
|
|
|
|
|
|
SINGLE |
|
|
| LAMP/ | |||
WHITE |
|
|
| FIXTURE | |||
|
| ||||||
REFLECTOR |
|
|
| LENGTH: | |||
|
|
|
|
|
| 32=T8 |
34=T12 (Nominal 48")
|
|
|
|
|
|
|
VOLTAGE: |
|
|
| OPTIONS: | ||
120 or 277 |
|
|
| Add appropriate | ||
|
|
|
|
| suffix to catalog | |
|
|
|
|
| no, ie: (GLR) | |
|
| BALLAST TYPE: |
| |||
|
| T12 |
| LE |
| |
1 | Lamp Mag. | <10THD | ||||
|
|
|
| <20THD | ||
1 | Lamp Elec. T8 |
| SO* | HI* | ||
LOL Dimming |
| PS | – |
*Instant Start Standard
Other dimming options, consult factory.
OPTIONS & ACCESSORIES
ACCESS PLATE: Top Wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify sepa- rately. Order Catalog Number: ACP CSP.
ELECTRICAL WIRING OPTIONS: Consult factory.FUSING: Internal
RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture
standard. SUFFIX: RF.
CONTINUOUS ROW INSTALLATION: For F type fixtures,
required between fixtures. Order Catalog Number: 1FCTRIM (each joint).
SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ14 S2 SPLAY TRIM.
AIR CLOSURE STRIP: SUFFIX ACS4 (factory installed).
DRYWALL KIT: Order Catalog Number: FK91X4. Request Folio
SPECIFICATIONS (continued)
AIR HANDLING: (VRA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp com- partment through fixture body ends.
MATERIALS: Chassis parts are
FINISH:
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and
SPECIFICATIONS
PERFORMANCE: In an installation of 1 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .67 with a spacing to mounting ratio of 1.9 perpendicular to the lamps. To meet IES
Job Information |
| Type: |
Lightolier a Genlyte Thomas Company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902