Lightolier VRA1G12LS132 Page 2 of, Options & Accessories, SPECIFICATIONS continued, Photometry

Models: VRA1G12LS132

1 2
Download 2 pages 16.56 Kb
Page 2
Image 2
Page 2 of 2
SECTION 2/Folio G05-37 REV. A

 

VR PARABOLIC VRA1G12LS132

Page 2 of 2

1'x4' RECESSED FLUORESCENT, 3" DEEP, 12 CELL (1 ROW) PARABOLIC LOUVER

 

STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE

PHOTOMETRY

 

LER = FP - 50.1

IW - 30.6

 

BF - 0.88

 

 

 

 

 

 

 

 

MODEL NO. VRA1G12LS132120SO Comparative yearly lighting energy cost per 1000 lumens = $4.80

 

 

 

 

 

coefficients of utilization — zonal cavity method

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RF

 

 

20

 

 

 

 

20

 

 

 

 

 

20

 

 

 

 

RC

 

 

80

 

 

 

 

50

 

 

 

 

 

30

 

 

 

 

RW

 

70

50

 

30

 

50

30

 

10

 

 

50

30

10

 

 

 

1

 

69

67

 

65

 

63

61

 

60

 

 

61

59

58

 

 

ratio

2

 

64

61

 

58

 

58

55

 

53

 

 

56

54

52

 

 

3

 

60

55

 

51

 

52

49

 

47

 

 

51

48

46

 

 

 

 

 

 

 

 

 

 

 

cavity

4

 

56

50

 

45

 

48

44

 

41

 

 

46

43

41

 

 

5

 

51

45

 

40

 

43

39

 

36

 

 

42

38

36

 

 

room

6

 

47

40

 

36

 

39

35

 

32

 

 

38

34

32

 

 

7

 

44

36

 

31

 

35

31

 

28

 

 

34

30

28

 

 

 

8

 

40

32

 

27

 

31

27

 

24

 

 

30

27

24

 

 

 

9

 

37

29

 

24

 

28

23

 

20

 

 

27

23

20

 

 

 

10

 

34

26

 

21

 

25

21

 

18

 

 

24

21

18

 

 

visual comfort probability

 

 

 

 

 

 

 

 

 

 

 

 

 

 

room size

 

 

 

 

 

ceiling height

 

 

 

 

ceiling height

 

 

 

 

W

 

 

L

 

 

 

8.5

10.0

13.0

16.0

 

 

8.5

10.0

13.0

 

16.0

 

20

 

 

20

 

 

 

95

94

92

88

 

 

90

85

81

 

80

 

20

 

 

30

 

 

 

96

94

93

90

 

 

90

88

82

 

77

 

20

 

 

40

 

 

 

96

95

93

92

 

 

90

88

83

 

79

 

 

20

 

 

60

 

 

 

96

95

94

92

 

 

90

88

84

 

79

 

30

 

 

20

 

 

 

95

94

92

87

 

 

90

87

85

 

82

 

30

 

 

30

 

 

 

96

95

94

89

 

 

90

89

85

 

79

 

30

 

 

40

 

 

 

96

95

94

91

 

 

90

88

86

 

80

 

30

 

 

60

 

 

 

97

96

95

91

 

 

91

88

86

 

80

 

 

30

 

 

90

 

lengthwise

 

97

96

95

91

 

crosswise

91

88

86

 

80

 

40

 

 

40

 

 

97

95

94

91

 

91

88

87

 

82

 

40

 

 

20

 

 

 

95

95

93

88

 

 

90

87

85

 

84

 

40

 

 

30

 

luminaries

 

96

95

94

90

 

luminaries

90

88

86

 

82

 

40

 

 

60

 

 

97

96

95

91

 

91

88

87

 

82

 

40

 

 

80

 

 

 

97

96

95

91

 

 

91

88

87

 

83

 

 

40

 

 

100

 

 

 

97

96

95

91

 

 

91

88

87

 

83

 

60

 

 

30

 

 

 

96

95

94

91

 

 

91

88

86

 

82

 

60

 

 

40

 

 

 

97

96

94

92

 

 

91

88

87

 

83

 

60

 

 

60

 

 

 

97

96

95

92

 

 

91

89

87

 

83

 

 

 

 

 

 

 

 

 

60

 

 

80

 

 

 

97

96

95

92

 

 

91

89

87

 

83

 

 

60

 

 

100

 

 

 

97

96

95

92

 

 

91

89

87

 

83

 

100

 

 

40

 

 

 

97

95

94

92

 

 

91

88

87

 

83

 

100

 

 

60

 

 

 

97

96

95

92

 

 

91

89

87

 

83

 

100

 

 

80

 

 

 

97

96

95

92

 

 

91

89

87

 

83

 

 

100

 

 

100

 

 

 

97

96

95

92

 

 

91

89

87

 

83

ORDERING INFORMATION

Explanation of Catalog Number. Example:VRA1G12LS132120SOGLR

VR

1

12

S

1

 

 

 

 

 

 

BODY STYLE:

 

BLANK = Standard

 

 

A=Air Handling

 

N = NYC Code

 

 

 

S=Static

 

 

 

 

 

 

 

 

 

 

 

 

VR:

FIXTURE

 

 

 

 

3" Deep

WIDTH

 

 

 

 

Pre-

 

 

 

 

 

 

anodized

 

 

 

 

 

 

Aluminum

 

 

 

 

 

 

Louver

 

 

 

 

 

 

for normal

 

 

 

 

 

 

VDT use

 

 

CEILING TYPE: G= Grid (lay-in T bar) F=Flanged (overlap)

Z spline and plaster frame

T=Slot grid or two-directional concealed T (see options)

NUMBER OF

CELLS:

1 row of

12 cells

LOUVER

FINISH: L=Low

Iridescence

Semi-specular

(standard)

P=Low

iridescence

specular

 

 

 

 

 

 

 

 

 

 

 

LAMP

 

 

 

 

 

 

QUANTITY

 

 

 

 

 

 

 

 

 

 

 

SINGLE

 

 

 

LAMP/

WHITE

 

 

 

FIXTURE

 

 

REFLECTOR

 

 

 

LENGTH:

 

 

 

 

 

 

32=T8

34=T12 (Nominal 48")

 

 

 

 

 

 

 

VOLTAGE:

 

 

 

OPTIONS:

120 or 277

 

 

 

Add appropriate

 

 

 

 

 

suffix to catalog

 

 

 

 

 

no, ie: (GLR)

 

 

BALLAST TYPE:

 

 

 

T12

 

LE

 

1

Lamp Mag.

<10THD

 

 

 

 

<20THD

1

Lamp Elec. T8

 

SO*

HI*

LOL Dimming

 

PS

*Instant Start Standard

Other dimming options, consult factory.

OPTIONS & ACCESSORIES

ACCESS PLATE: Top Wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify sepa- rately. Order Catalog Number: ACP CSP.

ELECTRICAL WIRING OPTIONS: Consult factory.

FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF.

RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture

standard. SUFFIX: RF.

CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are

required between fixtures. Order Catalog Number: 1FCTRIM (each joint).

SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ14 S2 SPLAY TRIM.

AIR CLOSURE STRIP: SUFFIX ACS4 (factory installed).

DRYWALL KIT: Order Catalog Number: FK91X4. Request Folio OA30-10.

CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS (continued)

AIR HANDLING: (VRA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp com- partment through fixture body ends.

MATERIALS: Chassis parts are die-formed embossed cold rolled steel. Housing is embossed for rigidity with all edges turned-in for safe handling. LOUVER: Pre-anodized aluminum (Coilzak@ or equal).

FINISH: Louver—low iridescence semi-specular anodized vertical grain alu- minum reflector sheet is standard. Reflector—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Chassis exterior—black baked polyester enamel.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

SPECIFICATIONS

PERFORMANCE: In an installation of 1 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .67 with a spacing to mounting ratio of 1.9 perpendicular to the lamps. To meet IES RP-1 recommended (basic) requirements for VDT areas the VCP (visual comfort probability) shall not be less than 91 either crosswise or lengthwise and the maximum average brightness at 65°, 75° and 85° shall not exceed 837, 82 and 41 candelas per square meter respectively in the 0°, 45° and 90° horizontal planes. Candelas at Nadir (0°) not to exceed 652.

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier VRA1G12LS132 Page 2 of, Options & Accessories, SPECIFICATIONS continued, Specifications, Photometry, Type

FAQ

What are the housing materials for the VRA1G12LS132 model?

The chassis parts are made of die-formed embossed cold rolled steel, while the housing is embossed for rigidity with all edges turned in for safe handling.

What are the options for fusing and radio interference filtering?

You can choose between internal fast-blow fusing (suffix GLR) or internal slow-blow fusing (suffix GMF) and opt for a radio interference filter (suffix RF).

What is the maximum average brightness in the 90 horizontal plane for this VRA1G12LS132 model?

The maximum average brightness at 85 shall not exceed 41 candelas per square meter.