Delta Electronics VFD-VL manual General Specifications

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 196
Image 196

 

 

 

 

Appendix A Specifications

 

 

 

 

General Specifications

 

 

 

Control System

1: V/f, 2: VF+PG, 3: SVC, 4: FOC+PG, 5: TQR+PG, 6:FOC+PM

 

 

 

Start Torque

Starting torque is 150% at 0.5Hz and 0Hz with control modes FOC + PG and

 

 

 

FOC+PM

 

 

 

 

 

 

 

Speed Control Range

1:100 Sensorless vector (up to 1:1000 when using PG card)

 

 

Characteristics

Speed Control Resolution

±0.5% Sensorless vector (up to±0.02% when using PG card)

 

 

Frequency Setting

Digital command ±0.01Hz, analog command: 1/4096(12-bit) of the max. output

 

 

 

Speed Response Ability

5Hz (up to 30Hz for vector control)

 

 

 

Max. Output Frequency

0.00 to 120.00Hz

 

 

 

Output Frequency Accuracy

Digital command ±0.005%, analog command ±0.5%

 

 

Control

Resolution

frequency

 

 

Torque Limit

Max. is 200% torque current

 

 

 

Torque Accuracy

±5%

 

 

 

Accel/Decel Time

0.00 to 600.00/0.0 to 6000.0 seconds

 

 

 

V/f Curve

Adjustable V/f curve using 4 independent points and square curve

 

 

 

Frequency Setting Signal

0-+10V, ±10V, 4~20mA

 

 

 

Brake Torque

About 20%

 

 

 

Motor Protection

Electronic thermal relay protection

 

 

 

Over-current Protection

The current forces 220% of the over-current protection and 300% of the rated

 

 

Characteristics

 

current

 

 

Ground Leakage Current

Higher than 50% rated current

 

 

 

Protection

 

 

 

 

 

 

 

Overload Ability

Constant torque: 150% for 60 seconds, variable torque: 200% for 3 seconds

 

 

Protection

Over-voltage Protection

Over-voltage level: Vdc > 400/800V; low-voltage level: Vdc < 200/400V

 

 

Over-temperature Protection

Built-in temperature sensor

 

 

 

Over-voltage Protection for

Varistor (MOV)

 

 

 

the Input Power

 

 

 

 

 

 

 

 

 

Compensation for the

Up to 5 seconds for parameter setting

 

 

 

Momentory Power Loss

 

 

 

 

 

 

Conditions

Protection Level

NEMA 1/IP20

 

 

Operation Temperature

-10°C to 45°C

 

 

 

 

 

Environmental

Storage Temperature

-20°C to 60°C

 

 

Installation Location

Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust

 

 

 

Ambient Humidity

Below 90% RH (non-condensing)

 

 

 

Vibration

9.80665m/s2 (1G) less than 20Hz, 5.88m/s2 (0.6G) at 20 to 50Hz

 

 

 

 

 

 

 

Approvals

 

 

 

 

 

 

Revision Nov. 2008, VLE1, SW V1.03

A-3

Page 196
Image 196
Delta Electronics VFD-VL manual General Specifications