Delta Electronics VFD-VL manual Group 9 Communication Parameters

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 70
Image 70

Chapter 4 Parameters

Group 9 Communication Parameters

 

 

 

 

Setting

VF

VFPG

SVC

FOCPG

TQCPG

FOCPM

 

Pr.

Explanation

Settings

Factory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09-00

Communication Address

1~254

1

09-01

Transmission Speed

4.8~115.2Kbps

9.6

09-02

Transmission Fault

0: Warn and keep operation

 

 

 

 

 

 

 

 

 

Treatment

1: Warn and ramp to stop

3

 

 

 

2: Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

3: No action and no display

 

 

 

 

 

 

 

09-03

Time-out Detection

0.0~100.0 sec

0.0

09-04

Communication Protocol

0: 7N1 (ASCII)

 

 

 

 

 

 

 

 

 

 

1: 7N2 (ASCII)

 

 

 

 

 

 

 

 

 

 

2: 7E1 (ASCII)

 

 

 

 

 

 

 

 

 

 

3: 7O1 (ASCII)

 

 

 

 

 

 

 

 

 

 

4: 7E2 (ASCII)

 

 

 

 

 

 

 

 

 

 

5: 7O2 (ASCII)

 

 

 

 

 

 

 

 

 

 

6: 8N1 (ASCII)

 

 

 

 

 

 

 

 

 

 

7: 8N2 (ASCII)

 

 

 

 

 

 

 

 

 

 

8: 8E1 (ASCII)

13

 

 

 

9: 8O1 (ASCII)

 

 

 

 

 

 

 

 

 

 

 

 

 

10: 8E2 (ASCII)

 

 

 

 

 

 

 

 

 

 

11: 8O2 (ASCII)

 

 

 

 

 

 

 

 

 

 

12: 8N1 (RTU)

 

 

 

 

 

 

 

 

 

 

13: 8N2 (RTU)

 

 

 

 

 

 

 

 

 

 

14: 8E1 (RTU)

 

 

 

 

 

 

 

 

 

 

15: 8O1 (RTU)

 

 

 

 

 

 

 

 

 

 

16: 8E2 (RTU)

 

 

 

 

 

 

 

 

 

 

17: 8O2 (RTU)

 

 

 

 

 

 

 

09-05

Response Delay Time

0.0~200.0ms

2.0

Revision Nov. 2008, VLE1, SW V1.03

4-15