Chapter 4 Parameters

Frequency

01-25 01-26

 

 

 

 

 

Time

 

 

01-24

01-27

 

 

 

 

01-29

Switch Frequency for S3/S4 Changes to S5

 

 

Unit: 0.01

Control

VF

VFPG SVC FOCPG FOCPM

 

 

Factory setting: 0.00

mode

 

 

 

 

 

 

 

Settings

0.00~120.00Hz

 

 

 

 

 

 

 

 

 

 

It is used to set the switch frequency between S4 and S5 for smooth stop.

It is recommended to set this parameter to the leveling speed of elevator.

F requenc y

 

 

01-25=S2

01-26=S3

 

01-12

01-13

 

decel. time

 

accel. time

01-29

 

 

 

 

 

Switch frequency

 

 

for S3/S 4 changes

 

01-27=S4

to S5

 

Time

 

 

01-24=S1

01-30=S5

 

 

01-28

Mode Selection when Frequency< Fmin

 

 

Control

VF

VFPG

SVC

Factory setting: 0

 

mode

 

 

 

 

 

 

Settings

0

Output Waiting

 

 

 

 

1

Zero-speed operation

 

 

 

 

2

Fmin (4th output frequency setting)

 

When the AC motor drive is at 0Hz, it will operate by this parameter.

When it is set to 1 or 2, voltage will be output by Fmin corresponding output voltage.

 

01-31

Deceleration Time when Operating without RUN

 

Command

 

 

 

 

Control

VF

VFPG SVC FOCPG FOCPM

 

mode

 

 

 

 

 

Settings

0.00~600.00 Sec

Unit: 0.01 Factory setting: 2.00

Revision Nov. 2008, VLE1, SW V1.03

4-35