Chapter 4 Parameters

It is used to set the accel./decel. time selection when stall prevention occurs at constant speed.

06-05

Over-torque Detection Selection (OT1)

 

 

Control

VF

VFPG

SVC

FOCPG TQCPG FOCPM

 

Factory setting: 0

mode

 

 

 

 

 

 

 

 

Settings

0

 

Over-Torque detection disabled.

 

 

 

 

1

 

Over-torque detection during constant speed operation, continue to

 

 

 

 

operate after detection

 

 

 

 

2

 

Over-torque detection during constant speed operation, stop

 

 

 

 

operation after detection

 

 

 

 

3

 

Over-torque detection during operation, continue to operate after

 

 

 

 

detection

 

 

 

 

4

 

Over-torque detection during operation, stop operation after

 

 

 

 

detection

 

 

 

 

 

 

 

06-06

Over-torque Detection Level (OT1)

 

Unit: 1

Control

VF

VFPG

SVC

FOCPG TQCPG FOCPM

 

Factory setting: 150

mode

 

 

 

 

 

 

 

 

Settings

10 to 250%

 

 

 

 

 

 

 

06-07

Over-torque Detection Time (OT1)

 

Unit: 0.1

Control

VF

VFPG

SVC

FOCPG TQCPG FOCPM

 

Factory setting: 0.1

mode

 

 

 

 

 

 

 

 

Settings

0.0 to 60.0 sec

 

 

 

 

 

 

 

 

 

 

 

 

06-08

Over-torque Detection Selection (OT2)

 

 

Control

VF

VFPG

SVC

FOCPG TQCPG FOCPM

 

Factory setting: 0

mode

 

 

 

 

 

 

 

 

Settings

0

 

Over-Torque detection disabled.

 

 

 

 

1

 

Over-torque detection during constant speed operation, continue to

 

 

 

 

operate after detection

 

 

 

 

2

 

Over-torque detection during constant speed operation, stop

 

 

 

 

operation after detection

 

 

 

 

3

 

Over-torque detection during operation, continue to operate after

 

 

 

 

detection

 

 

 

 

4

 

Over-torque detection during operation, stop operation after

 

 

 

 

detection

 

 

 

 

 

 

06-09

Over-torque Detection Level (OT2)

 

Unit: 1

Control

VF

VFPG

SVC

FOCPG TQCPG FOCPM

 

Factory setting: 150

mode

 

 

 

 

 

 

 

 

Settings

10 to 250%

 

 

 

 

 

 

 

 

 

 

4-64