Delta Electronics VFD-VL manual Applications for AC Reactor

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 209
Image 209

Appendix B Accessories

460V, 50/60Hz, 3-Phase

kW

HP

Fundamental

Max.

Inductance (mH)

continuous

 

 

Amps

3% impedance

5% impedance

 

 

Amps

 

 

 

5.5

7.5

18

27

1.5

2.5

 

 

 

 

 

 

7.5

10

18

27

1.5

2.5

 

 

 

 

 

 

11

15

25

37.5

1.2

2

 

 

 

 

 

 

15

20

35

52.5

0.8

1.2

 

 

 

 

 

 

18.5

25

45

67.5

0.7

1.2

 

 

 

 

 

 

22

30

45

67.5

0.7

1.2

 

 

 

 

 

 

30

40

80

120

0.4

0.7

 

 

 

 

 

 

37

50

80

120

0.4

0.7

 

 

 

 

 

 

45

60

100

150

0.3

0.45

 

 

 

 

 

 

55

75

130

195

0.2

0.3

 

 

 

 

 

 

75

100

160

240

0.15

0.23

 

 

 

 

 

 

B.4.3 Applications for AC Reactor

Connected in input circuit

Application 1

Question

 

 

When more than one AC motor drive is

When applying to one of the AC motor

connected to the same power, one of them

drive,

is ON during operation.

the charge current of capacity may cause

 

voltage ripple. The AC motor drive may

 

damage when over current occurs during

 

operation.

B-12

Revision Nov. 2008, VLE1, SW V1.03

Page 209
Image 209
Delta Electronics VFD-VL manual Applications for AC Reactor, 37.5 52.5 18.5 67.5 120 100 150 130 195 160 240