Delta Electronics VFD-VL manual Group 11 Advanced Parameters

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 72
Image 72

Chapter 4 Parameters

Group 11 Advanced Parameters

 

 

 

 

Setting

VF

VFPG

SVC

FOCPG

TQCPG

FOCPM

 

Pr.

Explanation

Settings

Factory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit 0=0: no function

0

 

 

 

 

 

 

 

Bit 0=1: ASR Auto tuning, PDFF enable

 

 

 

 

 

 

 

 

 

 

Bit 7=0: no function

 

 

 

 

 

 

 

 

 

System Control

Bit 7=1: When position control is enabled, it doesn’t need to set

 

 

 

 

 

 

 

11-00

Pr.07-02 (DC Brake Current Level)

 

 

 

 

 

 

 

 

 

 

Bit 15=0: when power is applied, it will detect the position of

 

 

 

 

 

 

 

 

 

 

magnetic field again

 

 

 

 

 

 

 

 

 

 

Bit 15=1: when power is applied, it will start from the magnetic

 

 

 

 

 

 

 

 

 

 

field position of previous power failure

 

 

 

 

 

 

 

11-01

Elevator Speed

0.10~3.00 m/s

1.00

 

 

 

 

11-02

Sheave Diameter

100~2000 mm

400

 

 

 

 

11-03

Mechanical Gear Ratio

1~100

1

 

 

 

 

11-04

Suspension Ratio

0: 1:1

1

 

 

 

 

1: 2:1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11-05

Inertial Ratio

1~300%

40

 

 

 

 

11-06

Zero-speed Bandwidth

0~40Hz

10

 

 

 

 

11-07

Low-speed Bandwidth

0~40Hz

10

 

 

 

 

11-08

High-speed Bandwidth

0~40Hz

10

 

 

 

 

11-09

PDFF Gain Value

0~200%

30

 

 

 

 

11-10

Gain for Speed Feed

0~500

0

 

 

 

 

Forward

 

 

 

 

11-11

Notch Filter Depth

0~20db

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11-12

Notch Filter Frequency

0.00~200.00Hz

0.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11-13

Low-pass Filter Time of

0.001~65.535s

0.500

Keypad Display

11-14

Motor Current at Accel.

50~200%

150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11-15

Elevator Acceleration

0.60~2.00m/s

0.75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11-16

Reserved

 

 

 

 

 

 

 

 

11-17

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11-18

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Revision Nov. 2008, VLE1, SW V1.03