Delta Electronics VFD-VL manual 00-14, Source of the Master Frequency Command, 00-15

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 83
Image 83

Chapter 4 Parameters

 

 

00-14

Source of the Master Frequency Command

 

Control

VF

VFPG SVC FOCPG FOCPM

Factory setting: 1

mode

 

 

 

 

 

Settings

1

RS-485 serial communication or digital keypad (KPVL-CC01)

 

 

 

2External analog input (Pr. 03-00)

3Digital terminals input (Pr.04-00~04-15) This parameter determines the drive’s master frequency source.

 

00-15

Source of the Operation Command

 

 

Control

VF

VFPG SVC FOCPG TQCPG FOCPM

Factory setting: 1

 

mode

 

 

 

 

 

 

Settings

1

External terminals

 

 

 

 

 

 

2

RS-485 serial communication or digital keypad (KPVL-CC01)

 

VFD-VL series is shipped without digital keypad and users can use external terminals or RS- 485 to control the operation command.

When the LED PU is light, the operation command can be controlled by the optional digital keypad (KPVL-CC01). Refer to appendix B for details.

4-28

Revision Nov. 2008, VLE1, SW V1.03

Page 83
Image 83
Delta Electronics VFD-VL manual 00-14, Source of the Master Frequency Command, 00-15, Source of the Operation Command