Delta Electronics VFD-VL manual System Control, Yes, Setting auto gain adjustment Pr.11-00=1

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 159
Image 159

Chapter 4 Parameters

Group 11 Advanced Parameters

 

 

 

 

11-00

System Control

 

 

 

 

 

Control

FOCPG

FOCPM

Factory Setting: 0

mode

 

 

 

 

Settings

Bit 0=0

No function

 

 

Bit 0=1 ASR Auto tuning, PDFF enable

 

 

Bit 7=0

No function

 

 

 

When position control is enabled, it doesn’t need to set Pr.07-02

Bit 7=1

(DC Brake Current Level)

 

Bit 15=0

when power is applied, it will detect the position of magnetic field

again

 

Bit 15=1

when power is applied, it will start from the magnetic field

position of previous power failure

 

Bit 0=1: PDFF function is enabled and system will generate an ASR setting, Pr. 10-11~10-16

will be invalid and Pr.11-09 to 11-10 will be valid.

When Pr.11- 00

NO

 

 

 

is set Bit 0=1

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting auto gain adjustment

Pr.11-00=1

Adjust Pr.11- 06, 11- 07 and 11- 08 separately by s peed response

Adjust by requirement

Pr.11-09, Pr. 11-10 (PDFF function)

Adjust by requirement Pr.10-17 (A SR1/ASR2 s wi tc h frequency)

Pr.10- 20: Zer o speed/ASR1 width adjustment

Pr.10- 21: ASR1/ASR2 width adjustment

Adjust by requirement Pr.07-25~28 (torque li mit)

Adjust gain value by manual Pr.11-00=0 (fac tory s etting)

Adjust Pr.10-11, 10- 12, 10- 13, 10-14, 10-15 and 10-16 separately by s peed response

Adjust by requirement Pr.10- 18 (for general, no need to adjus t)

4-104

Revision Nov. 2008, VLE1, SW V1.03

Page 159