Delta Electronics VFD-VL manual Group 2 Digital Input/Output Parameters, Vfpg SVC Focpg Tqcpg

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 60
Image 60

Chapter 4 Parameters

Group 2 Digital Input/Output Parameters

 

 

Pr.

Explanation

Settings

Factory

VF

VFPG

SVC

FOCPG

TQCPG

FOCPM

 

 

 

 

 

 

 

 

 

 

Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02-00

2-wire/3-wire Operation

0: FWD/STOP, REV/STOP

0

 

 

 

Control

1: FWD/STOP, REV/STOP (Line Start Lockout)

 

 

 

 

 

 

 

 

 

 

 

2: RUN/STOP, REV/FWD

 

 

 

 

 

 

 

 

 

 

 

3: RUN/STOP, REV/FWD (Line Start Lockout)

 

 

 

 

 

 

 

 

 

 

 

4: 3-wire

 

 

 

 

 

 

 

 

 

 

 

5: 3-wire (Line Start Lockout)

 

 

 

 

 

 

 

 

02-01

Multi-Function Input

0: no function

1

 

 

 

Command 1 (MI1)

1: multi-step speed command 1

 

 

 

 

 

(it is Stop terminal for 3-wire

 

 

 

 

 

2: multi-step speed command 2

 

 

 

 

 

operation)

 

 

 

 

 

 

 

 

 

 

 

 

 

02-02

Multi-Function Input

3: multi-step speed command 3

2

 

 

 

 

Command 2 (MI2)

4: multi-step speed command 4

 

 

 

02-03

Multi-Function Input

5: Reset

3

 

 

 

Command 3 (MI3)

6: JOG command

 

 

 

02-04

Multi-Function Input

7: acceleration/deceleration speed inhibit

4

 

 

 

 

Command 4 (MI4)

8: the 1st, 2nd acceleration/deceleration time selection

 

 

 

02-05

Multi-Function Input

9: the 3rd, 4th acceleration/deceleration time selection

0

 

 

 

 

10: EF input (07-28)

 

 

 

 

Command 5 (MI5)

 

 

 

 

11: Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02-06

 

12: Stop output

 

Multi-Function Input

13: Disable auto accel./decel. function

 

 

 

 

 

 

 

 

 

 

14: Reserved

0

 

 

 

 

 

 

 

 

 

Command 6 (MI6)

 

 

 

 

 

 

 

 

 

15: operation speed command form AUI1

 

 

 

 

 

 

 

 

 

 

 

 

16: operation speed command form ACI

 

 

 

02-07

Multi-Function Input

17: operation speed command form AUI2

0

 

 

 

 

Command 7 (MI7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02-08

Multi-Function Input

18: Emergency Stop (07-28)

0

 

 

 

Command 8 (MI8) (specific

19-23: Reserved

 

 

 

 

 

 

 

 

 

 

terminal for Enable)

24: FWD JOG command

 

 

 

 

 

 

25: REV JOG command

 

 

 

 

 

 

26: Reserved

 

 

 

 

 

 

 

 

 

 

 

27: ASR1/ASR2 selection

 

 

 

 

 

 

28: Emergency stop (EF1) (Motor coasts to stop)

 

 

 

 

 

29-30: Reserved

 

 

 

 

 

 

 

 

 

 

 

31: High torque bias (by Pr.07-21)

 

 

 

 

 

32: Middle torque bias (by Pr.07-22)

 

 

 

 

 

33: Low torque bias (by Pr.07-23)

 

 

 

 

 

34-37: Reserved

 

 

 

 

 

 

 

 

 

 

 

38: Disable write EEPROM function

 

 

 

 

 

39: Torque command direction

 

 

 

 

 

 

 

 

 

 

40: Enable drive function

 

 

 

 

 

41: Reserved

 

 

 

 

 

 

 

 

 

 

 

42: Mechanical brake

 

 

 

 

 

43: EPS function

 

 

02-09

Digital Input Response Time

0.001~ 30.000 sec

0.005

 

02-10

Digital Input Operation

0 ~ 65535

0

Direction

 

 

 

 

 

 

 

 

 

02-11

Multi-function Output 1 RA,

0: No function

11

RB, RC(Relay1)

1: Operation indication

 

 

02-12

Multi-function Output 2

2: Operation speed attained

1

MRA, MRC (Relay2)

3: Desired frequency attained 1 (Pr.02-25)

 

 

02-13

Multi-function Output 3

4: Desired frequency attained 2 (Pr.02-27)

0

 

(MO1)

5: Zero speed (frequency command)

 

 

 

 

 

 

6: Zero speed with stop (frequency command)

 

 

 

 

 

 

7: Over torque (OT1) (Pr.06-05~06-07)

 

 

 

 

 

8: Over torque (OT2) (Pr.06-08~06-10)

 

02-14

Multi-function Output 4

9: Drive ready

0

 

 

 

(MO2)

10: User-defined Low-voltage Detection (LV)

 

 

 

 

 

11: Malfunction indication

 

02-15

Multi-function Output 5

12: Mechanical brake release (Pr.02-29, Pr.02-30)

0

 

 

 

(MO3)

13: Overheat (Pr.06-14)

 

Revision Nov. 2008, VLE1, SW V1.03

4-5

Page 60
Image 60
Delta Electronics VFD-VL manual Group 2 Digital Input/Output Parameters, Vfpg SVC Focpg Tqcpg