Chapter 4 Parameters

Settings

Functions

 

Descriptions

20

Warning Output

Active when the warning is detected.

 

 

 

21

Over-voltage Warning

Active when the over-voltage is detected.

 

 

 

 

22

Over-current Stall

Active when the over-current stall prevention is detected.

Prevention Warning

 

 

 

 

 

 

 

23

Over-voltage Stall

Active when the over-voltage stall prevention is detected.

prevention Warning

 

 

 

 

 

 

24

Operation Mode

Active when the operation command is controlled by external

Indication

terminal. (Pr.00-15≠0)

 

 

 

 

 

 

25

Forward Command

Active when the operation direction is forward.

 

 

 

26

Reverse Command

Active when the operation direction is reverse.

 

 

 

 

27

Output when Current >=

Active when current is

>= Pr.02-33.

 

Pr.02-33

 

 

28

Output when Current <

Active when current is

< Pr.02-33.

Pr.02-33

 

 

 

 

 

 

 

29

Output when frequency

Active when frequency is >= Pr.02-34.

>= Pr.02-34

 

 

 

 

 

 

30

Output when Frequency

Active when frequency is < Pr.02-34.

 

< Pr.02-34

 

 

31-32

Reserved

 

 

 

 

 

33

Zero Speed (actual

Active when the actual output frequency is 0. (the drive should

output frequency)

be at RUN mode)

 

 

 

 

 

 

34

Zero Speed with Stop

Active when the actual output frequency is 0 or Stop. (the

(actual output frequency)

drive should be at RUN mode)

 

 

 

 

35

Fault output option 1

Active when Pr.06-22 is ON.

 

 

 

36

Fault output option 2

Active when Pr.06-23 is ON.

 

 

 

37

Fault output option 3

Active when Pr.06-24 is ON.

 

 

 

38

Fault output option 4

Active when Pr.06-25 is ON.

 

 

 

 

39

Reserved

 

 

 

 

 

 

Revision Nov. 2008, VLE1, SW V1.03

4-45