Delta Electronics VFD-VL manual Capacity Formulas, When one AC motor drive operates one motor

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 245
Image 245

Appendix C How to Select the Right AC Motor Drive

C.1 Capacity Formulas

1. When one AC motor drive operates one motor

The starting capacity should be less than 1.5x rated capacity of AC motor drive

The starting capacity=

 

 

 

 

k N

GD

2

 

 

 

 

TL +

375

 

 

 

973 ⋅η ⋅ cosϕ

N

⎟ ≤ 1.5 ⋅ the _ capacity _ of _ AC _ motor _ drive(kVA) tA

2.When one AC motor drive operates more than one motor

2.1The starting capacity should be less than the rated capacity of AC motor drive

„Acceleration time 60 seconds

The starting capacity=

k N

 

ns

 

[nT + ns(ks − 1)] = PC11

+

(ks − 1)

≤ 1.5 ⋅ the _ capacity _ of _ AC _ motor _ drive(kVA)

η ⋅ cosϕ

nT

 

 

 

 

 

 

„Acceleration time 60 seconds

The starting capacity=

k N

 

ns

 

[nT + ns(ks − 1)] = PC11

+

(ks − 1)

the _ capacity _ of _ AC _ motor _ drive(kVA)

η ⋅ cosϕ

nT

 

 

 

 

 

 

2.2The current should be less than the rated current of AC motor drive(A)

„Acceleration time 60 seconds

nS

≤ 1.5 ⋅ the _ rated _ current _ of _ AC _ motor _ drive( A)

nT + IM 1+

kS 1⎟⎥

nT

⎠⎦

 

„Acceleration time 60 seconds

nS

the _ rated _ current _ of _ AC _ motor _ drive( A)

nT + IM 1+

kS 1⎟⎥

nT

⎠⎦

 

C-2

Revision Nov. 2008, VLE1, SW V1.03

Page 245
Image 245
Delta Electronics VFD-VL Capacity Formulas, When one AC motor drive operates one motor, „ Acceleration time ≧60 seconds