Image 61

Chapter 4 Parameters

 

 

Pr.

Explanation

Settings

Factory

VF

VFPG

SVC

FOCPG

TQCPG

FOCPM

 

 

 

 

 

 

 

 

 

 

Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14: Brake chopper signal

0

02-16

Multi-function Output 6

15: Motor-controlled magnetic contactor output

0

 

 

 

(MO4)

16: Slip error (oSL)

 

 

 

 

 

 

17: Malfunction indication 1

 

 

 

 

 

18: Reserved

 

 

 

 

 

 

 

 

 

 

 

19: Brake chopper output error

 

02-17

Multi-function Output 7

20: Warning output

0

 

 

 

(MO5)

21: Over voltage warning

 

02-18

Multi-function Output 8

22: Over-current stall prevention warning

0

 

 

 

 

 

 

(MO6)

23: Over-voltage stall prevention warning

 

 

 

 

 

 

02-19

Multi-function Output 9

24: Operation mode indication (Pr.00-15≠0)

0

 

 

 

(MO7)

25: Forward command

 

02-20

Multi-function Output 10

26: Reverse command

0

 

 

 

(MO8)

27: Output when current >= Pr.02-33

 

02-21

Multi-function Output 11

28: Output when current < Pr.02-33

0

 

 

 

(MO9)

29: Output when frequency >= Pr.02-34

 

02-22

Multi-function Output 12

30: Output when frequency < Pr.02-34

0

 

 

 

(MO10)

31-32: Reserved

 

 

 

 

 

 

 

 

 

 

 

33: Zero speed (actual output frequency)

 

 

 

 

 

 

34: Zero speed with Stop (actual output frequency)

 

 

 

 

 

 

35: Fault output option 1 (Pr.06-22)

 

 

 

 

 

36: Fault output option 2 (Pr.06-23)

 

 

 

 

 

37: Fault output option 3 (Pr.06-24)

 

 

 

 

 

38: Fault output option 4 (Pr.06-25)

 

 

 

 

 

39: Reserved

 

 

 

 

 

 

 

 

 

 

 

40: Speed attained (including zero speed)

 

 

 

 

 

 

41: Reserved

 

 

 

 

 

 

 

 

02-23

Multi-output Direction

0 ~ 65535

0

02-24

Serial Start Signal Selection

0: by FWD/REV

0

 

 

1: by Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02-25

Desired Frequency Attained

0.00 ~ 120.00Hz

60.00/

 

 

 

 

1

 

50.00

 

 

 

 

 

 

02-26

The Width of the Desired

0.00 ~ 120.00Hz

2.00

 

 

 

 

Frequency Attained 1

 

 

 

 

 

 

 

 

02-27

Desired Frequency Attained

0.00 ~ 120.00Hz

60.00/

 

 

 

 

2

 

50.00

 

 

 

 

 

 

02-28

The Width of the Desired

0.00 ~ 120.00Hz

2.00

 

 

 

 

Frequency Attained 2

 

 

 

 

 

 

 

 

02-29

Brake Release Delay Time

0.000~65.000 Sec

0.250

when Elevator Starts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02-30

Brake Engage Delay Time

0.000~65.000 Sec

0.250

 

 

 

when Elevator Stops

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02-31

Turn On Delay of Magnetic

0.000~65.000 Sec

0.200

 

 

 

Contactor between Drive

 

 

 

 

 

 

 

 

 

 

and Motor

 

 

 

 

 

 

 

 

02-32

Turn Off Delay of Magnetic

 

0.200

Contactor between Drive

0.000~65.000 Sec

 

 

 

 

 

 

 

 

 

 

and Motor

 

 

 

 

 

 

 

 

02-33

Output Current Level Setting

0~100%

0

 

 

 

for External Terminals

 

 

 

 

 

 

 

 

02-34

Output Boundary for

0.00~+-120.00Hz (it is motor speed when using with PG)

0.00

 

 

 

External Terminals

 

 

 

 

 

 

 

 

02-35

Detection Time of

0.00~10.00 Sec

0.00

 

 

 

Mechanical Brake

 

 

 

 

 

 

 

 