Delta Electronics VFD-VL manual 02-25, 02-26, 02-27, 02-28, 02-29, 02-30

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 102
Image 102

Chapter 4 Parameters

Contr oller

 

Signal output

 

FW D/REV

 

Enable

 

Driv er

 

Multifunction

 

output/input

 

FW D/REV

 

Enable

 

Multifunction

 

output=15

02-31

Motor

 

Electr omagnetic

 

valv e

 

 

no v ol tage output

Contr oller

 

Signal output

 

FW D/REV

 

Enable

 

Driv er

 

Multifunction

 

output/input

 

FW D/REV

 

Enable

 

Multifunction

 

output=15

 

Motor

 

Electromagnetic

 

valv e

02-31

 

02-25

Desired Frequency Attained 1

Unit: 0.01

Control

VF

VFPG

SVC

FOCPG FOCPM

Factory setting: 60.00/50.00

mode

 

 

 

 

 

 

 

 

 

 

02-26

The Width of the Desired Frequency Attained 1

Unit: 0.01

Control

VF

VFPG

SVC

FOCPG FOCPM

Factory setting: 2.00

mode

 

 

 

 

 

 

02-27

Desired Frequency Attained 2

Unit: 0.01

Control

VF

VFPG

SVC

FOCPG FOCPM

Factory setting: 60.00/50.00

mode

 

 

 

 

 

 

 

 

 

 

02-28

The Width of the Desired Frequency Attained 2

Unit: 0.01

Control

VF

VFPG

SVC

FOCPG FOCPM

Factory setting: 2.00

mode

 

 

 

 

 

 

 

Settings

 

 

0.00 ~ 120.00Hz

 

 

 

 

 

 

 

 

Once output frequency reaches desired frequency and the corresponding multi-function output terminal is set to 3 or 4 (Pr.02-11~Pr.02-22), this multi-function output terminal will be ON.

02-29

Brake Release Delay Time when Elevator Starts

Unit:0.001

Control

VF

VFPG

SVC

FOCPG TQCPG FOCPM

Factory setting: 0.250

mode

 

 

 

 

 

 

02-30

Brake Engage Delay Time when Elevator Stops

Unit:0.001

Control

VF

VFPG

SVC

FOCPG TQCPG FOCPM

Factory setting: 0.250

mode

 

 

 

 

 

 

 

 

Settings

 

0.000~65.000 Sec

 

 

 

 

 

 

 

 

Revision Nov. 2008, VLE1, SW V1.03

4-47

Page 102
Image 102
Delta Electronics VFD-VL manual 02-25, 02-26, 02-27, 02-28, 02-29, 02-30