Delta Electronics VFD-VL manual 02-10, MI8 MI7 MI6 MI5 MI4 MI3 MI2 MI1 REV, 02-11, 02-12

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 97
Image 97

Chapter 4 Parameters

02-10

Digital Input Operation Direction

Unit: 1

Control

VF

VFPG SVC FOCPG TQCPG FOCPM

Factory setting: 0

mode

 

 

 

 

Settings

0 ~ 65535

 

 

 

 

 

This parameter is used to set the input signal level and it won’t be affected by the SINK/SOURCE status.

Bit0 is for FWD terminal, bit1 is for REV terminal and bit2 to bit9 is for MI1 to MI8. User can change terminal status by communicating.

For example, MI1 is set to 1 (multi-step speed command 1), MI2 is set to 2 (multi-step speed command 2). Then the forward + 2nd step speed command=1001(binary)=9 (Decimal). Only need to set Pr.02-10=9 by communication and it can forward with 2nd step speed. It doesn’t need to wire any multi-function terminal.

 

bit9

 

bit8

bit7

bit6

bit5

bit4

bit3

bit2

bit1

bit0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MI8

 

MI7

MI6

MI5

MI4

MI3

MI2

MI1

REV

FWD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02-11

 

Multi-function Output 1 RA, RB, RC (Relay1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Setting: 11

 

 

 

02-12

 

Multi-function Output 2 MRA, MRC (Relay2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Setting: 1

02-13Multi-function Output 3 (MO1)

02-14Multi-function Output 4 (MO2)

02-15Multi-function Output 5 (MO3) (need to use with EMVL-IODA01)

02-16Multi-function Output 6 (MO4) (need to use with EMVL-IODA01)

02-17Multi-function Output 7 (MO5) (need to use with EMVL-IODA01)

02-18Multi-function Output 8 (MO6) (need to use with EMVL-IODA01)

02-19Multi-function Output 9 (MO7) (need to use with EMVL-IODA01)

02-20Multi-function Output 10 (MO8) (need to use with EMVL-IODA01)

02-21Multi-function Output 11 (MO9) (need to use with EMVL-IODA01)

02-22Multi-function Output 12 (MO10) (need to use with EMVL-IODA01)

Factory Setting: 0

Settings 0-41

Settings

0:No function

1:Operation indication

VF

VFPG

Control Mode

SVC

FOCPG

TQCPG

FOCPM

 

 

 

 

4-42

Revision Nov. 2008, VLE1, SW V1.03

Page 97
Image 97
Delta Electronics VFD-VL manual 02-10, MI8 MI7 MI6 MI5 MI4 MI3 MI2 MI1 REV, 02-11, 02-12