Chapter 4 Parameters

 

 

 

10-08

Encoder Slip Detection Time

Unit: 0.1

 

 

 

 

 

 

Control

VFPG

SVC

FOCPG FOCPM

Factory Setting: 0.5

mode

 

 

 

 

 

 

Settings

0.0 to 10.0 sec

 

10-09

Encoder Stall and Slip Error Treatment

 

 

 

 

 

 

 

Control

VFPG

SVC

FOCPG FOCPM

Factory Setting: 2

mode

 

 

 

 

 

 

Settings

0

 

Warn and keep operating

 

 

 

1

 

Warn and RAMP to stop

 

 

 

2

 

Warn and COAST to stop

 

 

 

 

 

 

 

When the value of (rotation speed – motor frequency) exceeds Pr.10-07 setting, detection time exceeds Pr.10-08 or motor frequency exceeds Pr.10-05 setting, it will start to accumulate time. If detection time exceeds Pr.10-06, the encoder feedback signal error will occur. Refer to Pr.10-09 encoder stall and slip error treatment.

10-10Mode Selection for UVW Input

Control VFPG

FOCPG TQCPG FOCPM

Factory Setting: 0

mode

 

 

 

Settings

0

Z signal is at the falling edge of U-phase

 

 

1

Z signal is at the rising edge of U-phase

 

 

 

 

 

Setting 0: when the operation is U->V->W, Z signal is at the falling edge of U-phase.

Setting 1: when the operation is U->V->W, Z signal is at the rising edge of U-phase.

Pr.10- 10=1

 

 

U

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Z Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Z Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.10- 10=0

 

 

 

 

 

 

10-11

ASR (Auto Speed Regulation) Control (P) of Zero Speed

 

Unit: 0.1

 

 

 

 

 

 

 

 

 

 

 

 

 

Control

VF

VFPG SVC FOCPG FOCPM

Factory Setting: 100.0

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

Settings

0.0 to 500.0%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 