Delta Electronics VFD-VL manual Reset, EEE Fault code 5 E, Eeef a u l t code 6 3 E

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 186
Image 186

Chapter 6 Fault Code Information and Maintenance

Display

Description

 

 

 

 

 

illegal communication address

 

PCESl a v e EF a u l t EE

 

FEEE F a u l t C o d e : 5 E7

Corrective Actions:

 

Check if the communication address is correct.

 

Communication time-out

 

PCET i me EOu t u l t EE

 

 

 

FEEE F a u l t C o d e : 5 E8

Corrective Actions:

 

 

Check if the wiring for the communication is correct.

 

 

Keypad (KPVL-CC01) communication time-out

 

PUET i me EOu t u l t EE

Corrective Actions:

 

FEEEF a u l t Co d e : 5E9

 

1.

Check if the wiring for the communication is correct

2.Check if there is any wrong with the keypad

Brake chopper fail

Br k Ch o Ep p e r FEEa i El

Corrective Actions:

F EEE F a u l t C o d e : 6 0E

Press RESET key to correct it. If fault code is still displayed

 

 

on the keypad, please return to the factory.

 

 

Safety loop error

 

Sa f e t y ERe l a y EEr r

Corrective Actions:

 

 

 

 

FEEEF a u l t C o d e : 6 3E

1.

Check if the jumper JP18 is short circuit.

2.Re-power on to try it. If fault code is still displayed on the keypad, please return to the factory.

 

 

Mechanical brake error

 

 

Corrective Actions:

M

e c h e Br a k e u Fa i l E

1.

Check if the mechanical brake signal is correct.

F

EEE F a u l t C o d e : 6 4E

2.Check if the detection time setting of mechanical brake (Pr.02-35) is correct.

 

 

PG hardware error

 

Gc H BEr r o r Fa i l E

Corrective Actions:

P

1.

Check if the wiring of PG feedback is correct.

F

EEE F a u l t C o d e : 6 5E

2.

If fault code is still displayed on the keypad with

 

 

 

correct PG feedback, please return to the factory.

6.1.2 Reset

There are three methods to reset the AC motor drive after solving the fault:

STOP

1.Press RESET key on KPVL-CC01.

2.Set external terminal to “RESET” and then set to be ON.

3.Send “RESET” command by communication.

Revision Nov. 2008, VLE1, SW V1.03

6-9

Page 186
Image 186
Delta Electronics VFD-VL manual Reset, EEE Fault code 5 E, Eeef a u l t code 6 3 E