Delta Electronics VFD-VL manual 06-30, Setting Method of Fault Output, Bit Fault code

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 124
Image 124

Chapter 4 Parameters

59PU time-out (cP10)

60Brake chopper error (bF) 61-62 Reserved

63Safety loop error (Sry)

64Mechanical brake error (MBF)

65PGF5 hardware error

It will record when the fault occurs and force stopping. For the Lv, it will record when it is operation, or it will warn without record.

06-30

Setting Method of Fault Output

 

Control

VF

VFPG

SVC FOCPG TQCPG FOCPM

Factory setting: 0

mode

 

 

 

 

 

 

Settings

0

 

By settings of Pr.06-22~06-25

 

 

 

1

 

By the binary setting

 

 

 

 

 

 

 

It is used with the settings 35~38 of Pr.02-11~02-22 (Multi-function Output). The fault output selection 1~4 corresponds to Bit 0~3.

This parameter provides two setting methods for the fault output: setting 0: it is set by the

settings of Pr.06-22~Pr.06-25; setting 1: it is set by the binary setting and please refer to the following example for details.

Example:

Assume that

Pr.02-15 (Multi-function Output 5 (MO3)) is set to 35 Fault output option 1 (Pr.06-22). Pr.02-17 (Multi-function Output 7 (MO5)) is set to 36 Fault output option 2 (Pr.06-23). Pr.02-19 (Multi-function Output 9 (MO7)) is set to 37 Fault output option 3 (Pr.06-24).

Pr.02-21 (Multi-function Output 11 (MO9)) is set to 38 Fault output option 4 (Pr.06-25). Assume that external faults output with the following signal: MO3=1, MO5=1, MO7=0 and MO9=1. The corresponding Bit 3~0 is 1011.

 

 

Bit 3

Bit 2

Bit 1

Bit 0

Fault code

 

 

 

 

 

 

 

 

 

 

-

-

-

-

0: No fault

 

 

 

 

 

 

 

1: Over-current during acceleration (ocA)

 

 

 

 

 

 

2: Over-current during deceleration (ocd)

 

0

0

0

1

3: Over-current during constant speed (ocn)

 

4: Ground fault (GFF)

 

 

 

 

 

 

 

 

 

 

 

 

5: IGBT short-circuit (occ)

 

 

 

 

 

 

 

6: Over-curent at stop (ocS)

 

 

0

0

1

0

7: Over-voltage during acceleration (ovA)

 

 

 

 

 

 

 

8: Over-voltage during deceleration (ovd)

 

Revision Nov. 2008, VLE1, SW V1.03

4-69