Delta Electronics VFD-VL manual 02-09

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 96
Image 96

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chapter 4 Parameters

 

Settings

 

Functions

 

 

 

 

 

Descriptions

 

41

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When drive receives RUN command, the corresponding

 

 

 

 

 

 

 

 

 

 

 

 

output terminal (setting 12) will be enabled after Pr.02-

42

 

Mechanical brake

 

 

 

29 time. It will check if this function is enabled within the

 

 

 

 

 

 

 

 

 

 

 

 

detection time (Pr.02-35). If NOT, the fault of mechanical

 

 

 

 

 

 

 

 

 

 

 

 

brake occurs and fault code “MBF” will be displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If power is cut during running, the drive will stop when

43

 

EPS function

 

 

 

 

 

 

DC bus voltage is less than low voltage level. After

 

 

 

 

 

 

 

power is cut, drive will run by the frequency depend on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EPS when EPS is applied and this function is ON.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F requenc y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

frequency

 

 

 

 

 

 

07-04

 

 

Time

 

 

 

 

 

 

07-03

 

 

 

 

 

 

 

 

 

 

output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(F WD/RE V)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02-29

 

 

 

02-30

 

 

 

 

 

 

 

 

 

 

multi-function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

output ter minal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d=12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mechanical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

brake

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

multi-function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

input terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d=42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T1< 02- 35

 

 

 

 

T2< 02- 35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02-09

 

Digital Input Response Time

 

 

 

 

 

 

 

 

Unit: 0.001

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control

VF

VFPG

SVC

FOCPG TQCPG FOCPM

 

 

Factory setting: 0.005

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Settings

0.001~ 30.000 sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This parameter is used for digital input terminal signal delay and confirmation. The delay time

is confirmation time to prevent some uncertain interferences that would result in error (except

for the counter input) in the input of the digital terminals (FWD, REV and MI1~8). Under this

condition, confirmation for this parameter could be improved effectively, but the response time

will be somewhat delayed.