Chapter 6 Fault Code Information and Maintenance

 

Display

 

Description

 

 

 

 

 

 

 

 

IGBT overheating

 

 

 

IGBT temperature exceeds protection level

 

 

40 to100HP: 100 oC

 

 

Corrective Actions:

 

He a t ESi n k Eo Ha t EE

1.

Ensure that the ambient temperature falls within the

 

 

specified temperature range.

 

FEEE Fa u l t C o d e : 1E7

 

 

2.

Make sure that the ventilation holes are not

 

 

 

obstructed.

3.Remove any foreign objects from the heatsinks and check for possible dirty heat sink fins.

4.Check the fan and clean it.

5.Provide enough spacing for adequate ventilation. IGBT hardware failure

 

I

GB

T

E

HW

E

E

r

r

e

n

EEE

Corrective Actions:

 

F

E

 

 

F

a

u

l

t

C

o

d

e

:

1

8E

 

EE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return to the factory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heatsink overheating

 

He

a

t

E

S

i

n

k

E

HW

E

Er

r

 

 

F

E

EE

F

a

u

l

t

C

o

d

e

:

1

9E

Corrective Actions:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return to the factory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan failure

F

a n EL o c k e d EEEEEE

Corrective Actions:

FEEE F a u l t C o d e : 2 E0

1. Make sure that the fan is not obstructed.

2.Return to the factory

Overload

The AC motor drive detects excessive drive output current.

NOTE: The AC motor drive can withstand up to 150% of

In v e r t e r Eo L EEEEE the rated current for a maximum of 60 seconds.

FEEE F a u l t C o d e : 2E1

Corrective Actions:

1.Check whether the motor is overloaded.

2.Take the next higher power AC motor drive model.

 

 

Motor 1 overload

T h e r ma l ERe l a y

1E

Corrective Actions:

1.

Check whether the motor is overloaded.

F EEEF a u l t C o d e : 2 2E

2.

Check whether the rated current of motor (Pr.05-01) is

 

 

 

suitable

3.Take the next higher power AC motor drive model.

Motor overheating

The AC motor drive detects that the internal temperature exceeds Pr.06-30 (PTC level)

Mo t o r EOv e r EHe a t E

Corrective Actions:

FEEEF a u l

t Co d e : 2 4E

1. Make sure that the motor is not obstructed.

 

 

2.Ensure that the ambient temperature falls within the specified temperature range.

3.Take the next higher power AC motor drive model.

Revision Nov. 2008, VLE1, SW V1.03

6-5

Page 182
Image 182
Delta Electronics VFD-VL manual EEE Fault code 2 E0, Eeef a u l t code 2 2 E