Chapter 4 Parameters

Group 3 Analog Input/Output Parameters

03-00

Analog Input 1

(AUI1)

 

 

 

Factory Setting: 1

 

 

 

 

03-01

Analog Input 2

(ACI)

 

 

 

Factory Setting: 0

 

 

 

 

03-02

Analog Input 3

(AUI2)

 

 

 

Factory Setting: 0

 

 

 

 

Settings

0:No function

1:Frequency command (torque limit under TQR control mode)

2:Torque command (torque limit under speed mode)

3:Torque compensation command

4-5: Reserved

6:P.T.C. thermistor input value

7:Positive torque limit

8:Negative torque limit

9:Regenerative torque limit

10:Positive/negative torque limit

11:Preload Input

VF

Control Mode

VFPG

SVC

FOCPG

TQCPG

FOCPM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When it is frequency command or TQR speed limit, the corresponding value for 0~± 10V/4~20mA is 0 – max. output frequency(Pr.01-00)

When it is torque command or torque limit, the corresponding value for 0~±10V/4~20mA is 0 – max. output torque (Pr.07-14).

When it is torque compensation, the corresponding value for 0~±10V/4~20mA is 0 – rated torque.

Revision Nov. 2008, VLE1, SW V1.03

4-51