Delta Electronics VFD-VL manual ~100.0%

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 67
Image 67

Chapter 4 Parameters

 

Pr.

Explanation

Settings

Factory

VF

VFPG

SVC

FOCPG

TQCPG

FOCPM

 

Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11: Low-voltage during acceleration (LvA)

 

 

 

 

 

 

 

 

 

 

12: Low-voltage during deceleration (Lvd)

 

 

 

 

 

 

 

 

 

 

13: Low-voltage during constant speed (Lvn)

 

 

 

 

 

 

 

 

 

 

14: Low-voltage at stop (LvS)

 

 

 

 

 

 

 

 

 

 

15: Phase loss (PHL)

 

 

 

 

 

 

 

 

 

 

16: IGBT heat sink over-heat (oH1)

 

 

 

 

 

 

 

 

 

 

17: Heat sink over-heat (oH2)(for 40HP above)

 

 

 

 

 

 

 

 

 

 

18: TH1 open loop error (tH1o)

 

 

 

 

 

 

 

 

 

 

19: TH2 open loop error (tH2o)

 

 

 

 

 

 

 

 

 

 

20: Fan error signal output

 

 

 

 

 

 

 

 

 

 

21: over-load (oL) (150% 1Min)

 

 

 

 

 

 

 

 

 

 

22: Motor over-load (EoL1)

 

 

 

 

 

 

 

 

 

 

23: Reserved

 

 

 

 

 

 

 

 

 

 

24: Motor PTC overheat (oH3)

 

 

 

 

 

 

 

 

 

 

25: Reserved

 

 

 

 

 

 

 

 

 

 

26: over-torque 1 (ot1)

 

 

 

 

 

 

 

 

 

 

27: over-torque 1 (ot2)

 

 

 

 

 

 

 

 

 

 

28: Reserved

 

 

 

 

 

 

 

 

 

 

29: Reserved

 

 

 

 

 

 

 

 

 

 

30: Memory write-in error (cF1)

 

 

 

 

 

 

 

 

 

 

31: Memory read-out error (cF2)

 

 

 

 

 

 

 

 

 

 

32: Isum current detection error (cd0)

 

 

 

 

 

 

 

 

 

 

33: U-phase current detection error (cd1)

 

 

 

 

 

 

 

 

 

 

34: V-phase current detection error (cd2)

 

 

 

 

 

 

 

 

 

 

35: W-phase current detection error (cd3)

 

 

 

 

 

 

 

 

 

 

36: Clamp current detection error (Hd0)

 

 

 

 

 

 

 

 

 

 

37: Over-current detection error (Hd1)

 

 

 

 

 

 

 

 

 

 

38: Over-voltage detection error (Hd2)

 

 

 

 

 

 

 

 

 

 

39: Ground current detection error (Hd3)

 

 

 

 

 

 

 

 

 

 

40: Auto tuning error (AuE)

 

 

 

 

 

 

 

 

 

 

41: PID feedback loss (AFE)

 

 

 

 

 

 

 

 

 

 

42: PG feedback error (PGF1)

 

 

 

 

 

 

 

 

 

 

43: PG feedback loss (PGF2)

 

 

 

 

 

 

 

 

 

 

44: PG feedback stall (PGF3)

 

 

 

 

 

 

 

 

 

 

45: PG slip error (PGF4)

 

 

 

 

 

 

 

 

 

 

46: PG ref input error (PGr1)

 

 

 

 

 

 

 

 

 

 

47: PG ref loss (PGr2)

 

 

 

 

 

 

 

 

 

 

48: Analog current input error (ACE)

 

 

 

 

 

 

 

 

 

 

49: External fault input (EF)

 

 

 

 

 

 

 

 

 

 

50: Emergency stop (EF1)

 

 

 

 

 

 

 

 

 

 

51: Reserved

 

 

 

 

 

 

 

 

 

 

52: Password error (PcodE)

 

 

 

 

 

 

 

 

 

 

53: Reserved

 

 

 

 

 

 

 

 

 

 

54: Communication error (cE1)

 

 

 

 

 

 

 

 

 

 

55: Communication error (cE2)

 

 

 

 

 

 

 

 

 

 

56: Communication error (cE3)

 

 

 

 

 

 

 

 

 

 

57: Communication error (cE4)

 

 

 

 

 

 

 

 

 

 

58: Communication Time-out (cE10)

 

 

 

 

 

 

 

 

 

 

59: PU time-out (cP10)

 

 

 

 

 

 

 

 

 

 

60: Brake chopper error (bF)

 

 

 

 

 

 

 

 

 

 

61-62: Reserved

 

 

 

 

 

 

 

 

 

 

63: Safety loop error (Sry)

 

 

 

 

 

 

 

 

 

 

64: Mechanical brake error (MBF)

 

 

 

 

 

 

 

 

 

 

65: PGF5 hardware error

 

 

 

 

 

 

 

06-22

Fault Output Option 1

0~65535 (refer to bit table for fault code)

0

06-23

Fault Output Option 2

0~65535 (refer to bit table for fault code)

0

06-24

Fault Output Option 3

0~65535 (refer to bit table for fault code)

0

06-25

Fault Output Option 4

0~65535 (refer to bit table for fault code)

0

06-26

PTC (Positive Temperature

0: Warn and keep operation

0

 

 

Coefficient) Detection

1: Warn and ramp to stop

 

 

 

 

 

 

 

 

 

Selection

 

 

 

 

 

 

 

 

06-27

PTC Level

0.0~100.0%

50.0

06-28

Filter Time for PTC

0.00~10.00sec

0.20

 

 

Detection

 

 

 

 

 

 

 

 

06-29

EPS Voltage

48.0~375.0Vdc

48.0

96.0~750.0Vdc

96.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06-30

Setting Method of Fault

0: By settings of Pr.06-22~06-25

0

 

 

Output

1: By the binary setting

 

 

 

 

 

 

 

4-12

Revision Nov. 2008, VLE1, SW V1.03