3 Tests and Diagnostics

3.9 Async Test

3.9Async Test

To execute the Async Test, select 7 from the DIAGNOSTIC TEST MENU, press Enter and follow the directions displayed on the screen. The Async test contains two subtests that test the asynchronous communication functions. Move the highlight bar to the subtest you want to execute and press Enter.

Subtests require the following data format:

Method:

Asynchronous

Speed:

38400BPS (Subtests 06, 07)

Data:

8 bits and one parity bit (EVEN)

 

 

Data pattern: 20h to 7Eh

Subtest 01

Wraparound (board)

 

 

 

 

 

NOTE: To execute this subtest an RS-232C wraparound connector

 

 

(34M741621G01) must be connected to the RS-232C port. The RS-232C

 

 

wraparound connector wiring diagram is described in Appendix F.

 

 

 

 

This subtest checks the data send/receive function through the wraparound

 

connector.

Subtest 02

Point to Point (send)

 

 

 

 

 

NOTE: To execute this subtest, two machines must be connected with an

 

 

RS-232C direct cable. One machine should be set as “send”(subtest 02)

 

 

and the other set as “receive” (subtest 03). The wiring diagram for the

 

 

RS-232C direct cable is described in Appendix F.

 

 

 

 

This subtest sends 20h through 7Eh data to the receive side, then receives the

 

sent data and compares it to the original data.

Subtest 03

Point to Point (receive)

 

This subtest is used with subtest 02 described above. This subtest receives the

 

data from the send side, then sends the received data.

Subtest 04

Interrupt Test

 

This subtest checks the Interrupt Request Level of IRQ 4, 3 and 5 from the

 

send side.

3-26

Satellite Pro M10 Series Maintenance Manual (960-431)

Page 132
Image 132
Toshiba M10 manual Tests and Diagnostics Async Test, Other set as receive subtest 03. The wiring diagram for