4 Replacement Procedures

4.34 TFT FL (Model 15.0 UXGA SHARP LQ150U1LW13)

4.34 TFT FL (Model 15.0 UXGA SHARP LQ150U1LW13)

CAUTION: When you replace the fluorescent lamp, wear finger covers or gloves to avoid contaminating or damaging the LCD panel. Be careful not to let dust or other foreign matter into the module.

Removing the TFT FL (Model 15.0 UXGA SHARP LQ150U1LW13)

To remove the TFT FL (Model 15.0 UXGA SHARP LQ150U1LW13), follow the steps below and refer to Figures 4-127 to 4-135.

1.Turn the LCD module upside down.

2.Remove the protective cover-S, the wire-protective tape. Be careful not protective covers and tapes you have

protective cover-G, the aluminum tape, and the to damage the TCP or ICs. (Dispose of the removed.)

Wire-protective tape

Protective cover-S

Protective cover-G

Aluminum sheet

Aluminum tape

Figure 4-127 Removing the covers and tapes

4-154

Satellite Pro M10 Series Maintenance Manual (960-431)

Page 366
Image 366