4.30 TFT FL (Model 15.0 XGA LG. Philips LP150X06 A2) | 4 Replacement Procedures |
4.30 TFT FL (Model 15.0 XGA LG. Philips LP150X06 A2)
CAUTION: When you replace the fluorescent lamp, wear finger covers or gloves to avoid contaminating or damaging the LCD panel. Be careful not to let dust or other foreign matter into the module.
Removing the TFT FL (Model 15.0 XGA LG. Philips LP150X06 A2)
To remove the TFT FL (Model 15.0 XGA LG. Philips LP150X06 A2), follow the steps below and refer to figures
1.Disassembly of Tape adhesive used for B/L Wire fixing. Pressure or stress should not be given on B/L Wire.
2.Disassembly of Cover shield (G). Pressure or stress should not be given on Gate TCP.
3.Disassembly of Cover shield (C). Pressure or stress should not be given on Source PCB. Usage of gloves with
4.Disassembly of Tape shield a Tape Adhesive used for Top case fixing. Pressure or stress should not be given on Top case during this process
Figure 4-82 Disassembly of outside tape and cover shield
Satellite Pro M10 Series Maintenance Manual |