2 Troubleshooting Procedures | 2.3 Power Supply Troubleshooting | |||
1st Battery |
|
|
| |
|
|
|
|
|
| Error code |
| Meaning |
|
|
|
|
| |
| 20h | Main battery overvoltage is detected. (Not supported) |
| |
|
|
|
| |
| 21h | Main battery charge current is more than 6.05 A. |
| |
|
|
|
| |
| 22h | Main battery discharge current is more than 0.5 A when there is no load. |
| |
|
|
|
| |
| 23h | Main battery charge current is more than 4.3 A when DC IN direct charge |
| |
|
| is off. |
|
|
| 24h | Current sensing IC is not normal. |
| |
|
|
|
| |
| 25h | Main battery charge current is more than 0.3A when the battery isn't |
| |
|
| being charged. |
|
|
2nd Battery |
|
|
| |
|
|
|
| |
| Error code |
| Meaning |
|
|
|
|
| |
| 30h | 2nd battery overvoltage is detected. (Not supported) |
| |
|
|
|
| |
| 31h | 2nd battery charge current is more than 6.05 A. |
| |
|
|
|
| |
| 32h | 2nd battery discharge current is more than 0.5 A when there is no load. |
| |
|
|
|
| |
| 33h | 2nd battery charge current is more than 3.1 A when DC IN direct charge |
| |
|
| is off. |
|
|
| 34h | Current sensing IC is not normal. |
| |
|
|
|
| |
| 35h | 2nd battery charge current is more than 0.3A when the battery isn't being |
| |
|
| charged. |
|
|
S3V output |
|
|
| |
|
|
|
| |
| Error code |
| Meaning |
|
|
|
|
| |
| 40h | S3V voltage is under or equal to 3.14V when the computer is turned on |
| |
|
| or off. |
|
|
| 45h | S3V voltage is under or equal to 3.14V when the computer is booting up. |
| |
|
|
|
|
|
Satellite Pro M10 Series Maintenance Manual |