| 2 Troubleshooting Procedures | 2.3 Power Supply Troubleshooting | |||
| 1st Battery | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
| 
 | Error code | 
 | Meaning | 
 | 
| 
 | 
 | 
 | 
 | |
| 
 | 20h | Main battery overvoltage is detected. (Not supported) | 
 | |
| 
 | 
 | 
 | 
 | |
| 
 | 21h | Main battery charge current is more than 6.05 A. | 
 | |
| 
 | 
 | 
 | 
 | |
| 
 | 22h | Main battery discharge current is more than 0.5 A when there is no load. | 
 | |
| 
 | 
 | 
 | 
 | |
| 
 | 23h | Main battery charge current is more than 4.3 A when DC IN direct charge | 
 | |
| 
 | 
 | is off. | 
 | 
 | 
| 
 | 24h | Current sensing IC is not normal. | 
 | |
| 
 | 
 | 
 | 
 | |
| 
 | 25h | Main battery charge current is more than 0.3A when the battery isn't | 
 | |
| 
 | 
 | being charged. | 
 | 
 | 
| 2nd Battery | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | |
| 
 | Error code | 
 | Meaning | 
 | 
| 
 | 
 | 
 | 
 | |
| 
 | 30h | 2nd battery overvoltage is detected. (Not supported) | 
 | |
| 
 | 
 | 
 | 
 | |
| 
 | 31h | 2nd battery charge current is more than 6.05 A. | 
 | |
| 
 | 
 | 
 | 
 | |
| 
 | 32h | 2nd battery discharge current is more than 0.5 A when there is no load. | 
 | |
| 
 | 
 | 
 | 
 | |
| 
 | 33h | 2nd battery charge current is more than 3.1 A when DC IN direct charge | 
 | |
| 
 | 
 | is off. | 
 | 
 | 
| 
 | 34h | Current sensing IC is not normal. | 
 | |
| 
 | 
 | 
 | 
 | |
| 
 | 35h | 2nd battery charge current is more than 0.3A when the battery isn't being | 
 | |
| 
 | 
 | charged. | 
 | 
 | 
| S3V output | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | |
| 
 | Error code | 
 | Meaning | 
 | 
| 
 | 
 | 
 | 
 | |
| 
 | 40h | S3V voltage is under or equal to 3.14V when the computer is turned on | 
 | |
| 
 | 
 | or off. | 
 | 
 | 
| 
 | 45h | S3V voltage is under or equal to 3.14V when the computer is booting up. | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
| Satellite Pro M10 Series Maintenance Manual  | 