4 Replacement Procedures

4.28 TFT FL (Model 14.1 XGA LG. Philips LP141X7-C1TO)

Installing the TFT FL (Model 14.1 XGA LG. Philips LP141X7-C1TO)

To install the TFT FL (Model 14.1 LG. XGA Philips LP141X7-C1TO), follow the steps below and refer to figures 4-69 to 4-72.

Attaching the double tape, lamp assembly, cover bottom, sheets, light guide, tape adhesive and board assembly

1.Attach the lamp assembly with the double tape (1). (Lamp housing fixing)

2.Attach the lamp assembly with the mold frame and connecting the low voltage wire with the mold frame (2).

CAUTION: Pressure or stress should not be given on the wire during this process.

3.Connect the cover bottom with the double tape (3). (grounding)

4.Connect the kapton tape with supporter main (4). (protection of wire (G))

5.Fix the cover bottom and screw (5).

CAUTION: Maximum value of torque with screw should be below 2.0kgf.cm.

6. Attach the sheets and light guide (6).

CAUTION: No penetration of foreign body is indispensable with no scratch on the surface of each sheet and light guide.

7.Attach the tape adhesive (7) used for sheets fixing.

8.Attach the board assembly (8).

CAUTION: Pressure or stress should not be given on the PCB and TCP.