Chapter 4 Parameters

06-22

Fault Output Option 1

Unit: 1

06-23

Fault Output Option 2

Unit: 1

06-24

Fault Output Option 3

Unit: 1

06-25

Fault Output Option 4

Unit: 1

Control

VF

VFPG SVC FOCPG TQCPG FOCPM

Factory setting: 0

mode

 

 

 

 

Settings

0 to 65535 sec (refer to bit table for fault code)

 

 

 

 

 

These parameters can be used with multi-function output (set Pr.02-11 to Pr.02-22 to 35-38) for the specific requirement. When the fault occurs, the corresponding terminals will be activated (It needs to convert binary value to decimal value to fill in Pr.06-22 to Pr.06-25).

 

Fault code

Bit0

Bit1

Bit2

Bit3

Bit4

Bit5

Bit6

 

 

current

Volt.

OL

SYS

FBK

EXI

CE

 

 

 

 

 

0: No fault

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1: Over-current during acceleration

 

 

 

 

 

 

 

 

(ocA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2: Over-current during deceleration

 

 

 

 

 

 

 

 

(ocd)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3: Over-current during constant speed

 

 

 

 

 

 

 

 

(ocn)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4: Ground fault (GFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5: IGBT short-circuit (occ)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6: Over-curent at stop (ocS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7: Over-voltage during acceleration

 

 

 

 

 

 

 

 

(ovA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8: Over-voltage during deceleration

 

 

 

 

 

 

 

 

(ovd)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9: Over-voltage during constant speed

 

 

 

 

 

 

 

 

(ovn)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10: Over-voltage at stop (ovS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11: Low-voltage during acceleration

 

 

 

 

 

 

 

 

(LvA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12: Low-voltage during deceleration

 

 

 

 

 

 

 

 

(Lvd)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13: Low-voltage during constant

 

 

 

 

 

 

 

 

speed (Lvn)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14: Low-voltage at stop (LvS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 