Chapter 4 Parameters

 

Setting of PG

PG signal type

Applicable PG card

Pr.08-00=1

Pr.08-00=3

 

 

signal type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10-00=4

SIN/COS+Endat

EMVL-PGS01

Motor will run

Motor won’t run

 

 

 

 

 

 

 

 

 

 

 

10-00=5

SIN/COS

EMVL-PGH01/02

Motor will run

Motor will run

 

 

 

 

 

 

 

 

 

 

 

10-00=6

SIN/COS +

EMVL-PGS01

Motor will run

Motor won’t run

 

 

Hiperface

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10-01

Encoder Pulse

 

 

 

Unit: 1

Control

VFPG

FOCPG TQCPG FOCPM

 

 

Factory Setting: 600

mode

 

 

 

 

 

 

 

 

 

Settings

1 to 20000

 

 

 

 

 

A Pulse Generator (PG) or encoder is used as a sensor that provides a feedback signal of the

motor speed. This parameter defines the number of pulses for each cycle of the PG control.

10-02Encoder Input Type Setting

Control VFPG

FOCPG TQCPG FOCPM

Factory Setting: 0

mode

 

 

 

Settings

0

Disable

 

1

2

3

4

Phase A leads in a forward run command and phase B leads in a reverse run command

FWDREV

A

For war d running B

Phase B leads in a forward run command and phase A leads in a reverse run command

FWDREV

A For war d running B

Phase A is a pulse input and phase B is a direction input. (low input=reverse direction, high input=forward direction)

FWDREV

A For war d running B

Phase A is a pulse input and phase B is a direction input. (low input=forward direction, high input=reverse direction)

FWDREV

A For war d running B

4-98

Revision Nov. 2008, VLE1, SW V1.03

Page 153
Image 153
Delta Electronics VFD-VL manual Motor will run Motor won’t run 10-00=5, Motor will run 10-00=6, 10-01, Encoder Pulse Unit