Chapter 4 Parameters

suspension ration 1:1

suspension ration 2:1

 

 

 

 

 

11-02

reel

 

reel

sheave diameter

 

 

 

 

 

 

pully

 

pully

 

 

 

 

 

 

 

pully

pully

 

 

load weight

 

load weight

 

carriage

 

 

 

 

carriage

 

 

 

 

 

11-05

Inertial Ratio

 

Unit: 1

Control

FOCPG

FOCPM

 

Factory Setting: 40

mode

 

 

 

 

 

Settings

1 to 300%

 

 

The load inertia can be calculated by the settings of motor parameter, Pr.11-02 Sheave Diameter, Pr.11-14 Motor Current at Accel. and Pr.11-15 Elevator Acceleration. This parameter can be used to adjust inertia ratio of load.

11-06

Zero-speed Bandwidth

Unit: 1

 

 

 

 

11-07

Low-speed Bandwidth

Unit: 1

 

 

 

 

11-08

High-speed Bandwidth

Unit: 1

 

 

 

 

Control

FOCPG FOCPM

Factory Setting: 10

mode

 

 

 

 

Settings

0 to 40Hz

 

 

 

 

 

After estimating inertia and set Pr.11-00=1 (auto tuning), user can adjust parameters Pr.11-06, 11-07 and 11-08 separately by speed response. The larger number you set, the faster response you will get. Pr.10-08 is the switch frequency for low-speed/high-speed bandwidth.

11-09

PDFF Gain Value

Unit: 1

 

 

 

 

Control

FOCPG

FOCPM

Factory Setting: 30

mode

 

 

 

 

Settings

0 to 200%

 

 

 

 

 

4-106