Chapter 4 Parameters

 

05-06

Rs of Motor

 

Unit: 0.001

 

Control

SVC

FOCPG

TQCPG

Factory setting: 0.000

 

mode

 

 

 

 

 

05-07

Rr of Motor

 

Unit: 0.001

 

 

 

 

 

 

 

Control

SVC

FOCPG

TQCPG

Factory setting: 0.000

 

mode

 

 

 

 

 

 

Settings

0.000~65.535Ω

 

 

 

 

 

 

05-08

Lm of Motor

 

Unit: 0.1

 

Control

SVC

FOCPG

TQCPG

Factory setting: 0.0

 

mode

 

 

 

 

05-09

Lx of Motor

 

Unit: 0.1

 

Control

SVC

FOCPG

TQCPG

Factory setting: 0.0

 

mode

 

 

 

 

 

 

Settings

0.0~6553.5mH

 

 

 

 

 

 

 

 

05-10

Torque Compensation Time Constant

Unit: 0.001

 

 

 

 

 

 

 

Control

SVC

 

 

Factory setting: 0.020

 

mode

 

 

 

 

 

 

Settings

0.001 to 10.000 sec

 

05-11

Slip Compensation Time Constant

Unit: 0.001

 

Control

SVC

 

 

Factory setting: 0.100

 

mode

 

 

 

 

 

 

Settings

0.001 to 10.000 sec

 

Setting Pr.05-10 and Pr.05-11 change the response time for the compensation.

When Pr.05-10 and Pr.05-11 are set to 10 seconds, its response time for the compensation will be the longest. But if the settings are too short, unstable system may occur.

05-12

Torque Compensation Gain

Unit: 1

Control

VF

VFPG

Factory setting: 0

mode

 

 

 

 

Settings

0 to10

 

 

This parameter may be set so that the AC motor drive will increase its voltage output to obtain

a higher torque.

 

 

 

 

05-13

Slip Compensation Gain

Unit: 0.01

Control

SVC

VFPG SVC

Factory setting: 0.00

mode

 

 

 

 

Settings

0.00 to10.00

 

 

 

 

 

Revision Nov. 2008, VLE1, SW V1.03

4-59