Chapter 4 Parameters

Settings

Functions

Descriptions

13

Disable auto

It is used to disable auto accel./decal. function.

accel./decel. function

 

 

 

 

 

14

Reserved

 

 

 

 

15

Operation speed

When this function is enabled, the source of the

command form AUI1

frequency will force to be AUI1.

 

 

 

 

16

Operation speed

When this function is enabled, the source of the

command form ACI

frequency will force to be ACI.

 

 

 

 

17

Operation speed

When this function is enabled, the source of the

command form AUI2

frequency will force to be AUI2.

 

 

 

 

18

Emergency Stop

When this function is enabled, the drive will ramp to stop

by Pr.07-28 setting.

 

 

 

 

 

19-23

Reserved

 

 

 

 

24

FWD JOG command

When this function is enabled, the drive will execute

forward Jog command.

 

 

 

 

 

25

REV JOG command

When this function is enabled, the drive will execute

reverse Jog command.

 

 

 

 

 

26

Reserved

 

 

 

 

27

ASR1/ASR2 selection

ON: speed will be adjusted by ASR 2 setting.

OFF: speed will be adjusted by ASR 1 setting.

 

 

 

 

 

28

Emergency stop (EF1)

When it is ON, the drive will execute emergency stop. (it

(Motor coasts to stop)

will have fault code record)

 

 

 

 

29-30

Reserved

 

 

 

 

31

High torque bias (by

The high torque bias is according to the Pr.07-21

Pr.07-21)

setting.

 

 

 

 

32

Middle torque bias (by

The middle torque bias is according to the Pr.07-22

Pr.07-22)

setting.

 

 

 

 

33

Low torque bias (by

The low torque bias is according to the Pr.07-23 setting.

Pr.07-23)

 

 

 

 

 

34-37

Reserved

 

 

 

 

38

Disable write EEPROM

When this function is enabled, you can’t write into

function

EEPROM.

 

 

 

 

39

Torque command

When the torque command source is ACI, it can change

direction

torque direction by enabling this function.

 

 

 

 

 

 

When this function is enabled, the drive function can be

40

Enable drive function

executed. This function can be used with multi-function

output (setting Pr.02-11~Pr.02-14 to 15) and (Pr.02-31

 

 

 

 

and Pr.02-32).

 

 

 

4-40