Chapter 3 Operation and Start Up

Pr.10-19

Zero Speed Gain (P)

0~655.00%

NOTE: refer to the explanations in Pr.02-32

Pr.10-22

0.000~65.535sec

Operation Time of

 

Zero Speed

 

 

 

 

 

Pr.10-23

0.000~65.535sec

Filter Time of Zero

 

Speed

 

 

 

 

 

Pr.10-24

0: after the brake release set in Pr.02-29

Time for Zero Speed

1: after the brake signal input (Pr.02-01~02-08 is set to

Execution

42)

 

 

 

 

Pr.02-29

0.000~65.000 Sec

Brake Release Delay

 

Time when Elevator

 

Starts

 

 

 

NOTE: When Pr.10-24=0, the zero speed control needs to be used with Pr.02-29. (refer to the explanations in Pr.02-32)

„Function of the preload input

Please connect the signal of the preload signal to the external terminal of the AC motor drive (AUI1) and setting Pr.03-00=11, 07-19=1, 03-03, 03-06 and 03-09.

Pr.03-00

 

0: No function

Analog Input 1 (AUI1)

 

1: Frequency command (torque limit under TQR control

 

 

mode)

 

 

2: Torque command (torque limit under speed mode)

 

 

3: Torque compensation command

 

 

4-5: Reserved

 

 

6: P.T.C. thermistor input value

 

 

7: Positive torque limit

 

 

8: Negative torque limit

 

 

9: Regenerative torque limit

 

 

10: Positive/negative torque limit

 

 

 

 

 

 

11: Preload Input

 

 

 

 