Chapter 4 Parameters

When using multi-function input terminals to switch ASR1/ASR2, the diagram will be shown as

follows.

Setting multi-function input terminal to 17

(ASR1/ASR2 switch)

ON

OFF

OFF

ASR 1

 

ASR 2

 

ASR 1

 

 

 

 

 

 

 

 

 

 

 

0.1 sec

0.1 sec

10-18

ASR Primary Low Pass Filter Gain

Unit: 0.001

 

 

 

 

Control

VF

VFPG SVC FOCPG FOCPM

Factory Setting: 0.008

mode

 

 

 

 

Settings

0.000 to 0.350 sec

 

 

 

It defines the filter time of the ASR command.

 

When setting to 1, this function is disabled.

 

 

 

 

10-19

Zero Speed Gain (P)

Unit: 0.01

 

 

 

 

Control

FOCPM

 

Factory Setting: 80.00

mode

 

 

 

 

Settings

0.00 to 655.00%

 

 

 

When Pr.11-00 is set to Bit 7=1, Pr.10-19 is valid.

 

 

 

 

10-20

Zero Speed/ASR1 Width Adjustment

Unit: 0.01

 

 

 

 

Control

VFPG

FOCPG FOCPM

Factory Setting: 5.00

mode

 

 

 

 

Settings

0.0 to 120.00Hz

 

10-21

ASR1/ASR2 Width Adjustment

Unit: 0.01

 

 

 

 

Control

VFPG

FOCPG FOCPM

Factory Setting: 5.00

mode

 

 

 

 

Settings

0.0 to 120.00Hz

 

These two parameters are used to decide width of slope of ASR command during zero speed to low speed or Pr.10-17 to high speed.