Chapter 3 Operation and Start Up

3.3Auto-tuning Operations

3.3.1Flow Chart

Step 1 Basic parameter settings Step 2 Motor tuning

Sett ing all parameters to factory setting

Pr. 00 -02

Source of the Master

Frequency C omm and

Pr. 00 -14

Source of the

Operation C omm and

Pr.00- 15

MI/M O terminals Settings

Pr.02- 01~02- 08

Pr.02- 13~02- 22

Motor ty pe

PM

[PM/IM ]

 

 

IM

 

 

 

 

 

 

Sett ing t he relat ed informat ion of IM motor

Pr. 01 - 00~01-02

Pr.05 - 01~05- 04

IM M otor Aut o- tuning

Pr.05- 00

Control M ode Select ion

Pr.00 -09

Sett ing t he relat ed informat ion of PM motor

Pr.01 - 00~01-02

Pr.08 - 01~08-04

PM Motor Auto-t uning Pr.08- 00

Step 3 Encoder settings

Selection of speed feedbac k card

EMVL-PGABL EMVL-PGABO EMVL-PGH01 EMVL-PGS01

Encoder selection

Pr.10-00

Sett ing Encoder information

Pr.10 - 00~10- 02

Step 4 Multi- step speed settings

Sett ing s peed, accel/decel. t ime and S curve

Pr.04 -00~04- 15

Pr.01 -12~01- 19

Pr.01 -24~01- 30

Step 5 Trial run

Trial run

Step 6 Elevator tuning

Smooth test

Pr.11 -00 bit0=1 1 . tuning as start-up

Pr.11 -05~11 -08 2 . tuning as stop

Detection of the HOME position of Encoder

1 . us ing digital k eypad

2 . us ing external terminals

3-4