TROUBLESHOOTING
WARNING:Make sure that power is
turn off before proceeding....
OBSERVED PROBLEM
No spark when press in ignition button
WARNING: Turn off and let cool |
| CAUTION: Never use a wire, |
before servicing. Only a qualified ser- |
| needle, or similar object to clean |
vice person should service and repair |
| ODS/pilot. This can damage ODS/ |
fireplace. |
| pilot unit. |
|
|
|
POSSIBLECAUSE | REMEDY |
| |
1. No power to heater | 1. Check the electric power |
2. No battery in transmitter or battery isn’t | 2. Place or replace the battery. |
correctly assembly |
|
When | pressing the button of ignitor but- | 1. | Gas supply turned off or equipment 1. | Turn | on | gas | supply or | open | |
ton is | pressed, there is spark at ODS/ |
| shut off valve closed | 2. | equipment shutoff valve |
| |||
pilot but no ignition | 2. | Air in gas lines when installed. | Press ON/OFF button again |
| |||||
| until air | is removed . |
| ||||||
|
|
|
|
|
| ||||
|
|
|
| 3. Contact |
| local | propane/LP | gas | |
|
| 3. | Depleted gas supply |
| company |
|
|
| |
|
| 4 | Clean | ODS/pilot (see Cleaning and | |||||
|
|
|
| ||||||
|
| 4. | ODS/pilot is clogged |
| Maintenance,page 12 ) or replace | ||||
|
|
| ODS/pilot | assembly |
| ||||
|
|
|
|
|
|
ODS/pilot lights but flame is continuous igniting and the main burner couldn’t be lit.
5.Gas regulator setting is not correct
6.Pilot electrude position is not correct
7.Wire is not correct or loosen
8 Gas valve is damage
1.Thermocouple connection loose at control board
2.Pilot flame not touching thermcouple which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following
A)Low gas pressure
B)Dirty or partially clogged ODS/ pilot
3.Thermocouple damaged
4.Control valve damaged
5.Replace gas control
6.Replace Pilot
7.Check the wine and make wine correct.
8.Replace gas valve
1 . Hand tighten the connectors .
2.A) Contact local propane/LP gas company.
B)Clean ODS/pilot (see Cleaning and Maintenance, page 12) or replace ODS/pilot assembly
3.Replace thermocouple
4.Replace control valve
Burner does not light after ODS/pilot is lit
1.Burner orifice clogged
2.Inlet gas pressure is too low
3.Burner orifice diameter is too small
4.Thermocouple leads disconnected or improperly connected
5.Burners will not come in remote position
1 . C l e a n b u r n e r ( s e e C l e a n i n g and Maintenance, page 12) or replace burner orifice.
2.Contact local propane/LP gas company
3.Replace burner orifice
4.Reconnect leads (see wiring diagram)
5.Replace battery in transmitter and receiver