Procom EN250RYLB-O, EL250RYLB-O Installation, MinimumClearance to Wall, Check Gas Type

Models: EL250RYLB-O EN250RYLB-O

1 21
Download 21 pages 44.67 Kb
Page 7
Image 7
INSTALLATION

INSTALLATION

Figure 4 -Minimum Clearance to Wall NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system's circulating blower while using heater. This will help cir- culate the heat throughout the house .

CHECK GAS TYPE WARNING: A qualified service person must install heater. Follow all local codes.

Minimum Wall and Ceiling WARNING: Never install the heater:

in a bedroom or bathroom in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater in high traffic areas

in windy or drafty areas

Figure 4 -Minimum Clearance to Wall

Manual background CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist,may dis- color walls.

Manual background WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining side and back walls.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew. See Air for Combustion and Ventilation, pages 5 through 6.

CHECK GAS TYPE

Use only the type of gas indicated on the plate. If your gas supply can not meet that requirement, do not install heater. Call dealer where you bought heater from for proper heater type.

CLEARANCESTOCOMBUSTIBLES (Vent-Free Operation Only) Carefully follow the instructions below. This fireplace is a freestanding unit designed to set directly on the floor.

IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown in Figure 4. Measure from outermost point of fire- place top.

Minimum Wall and Ceiling

Clearances

(see Figure 4)

A. Clearances from outermost point of fireplace top to any combustible side wall should not be less than 12 inches.

B.Clearances from the fireplace top to the ceiling should not be less than 48 inches.

7

Page 7
Image 7
Procom EN250RYLB-O Installation, MinimumClearance to Wall, Check Gas Type, Minimum Wall and Ceiling Clearances