SECTION 2/Folio G05-50 REV. A

 

VR PARABOLIC VRA2G16LS26U

Page 2 of 2

2'x2' RECESSED FLUORESCENT, 4" DEEP, 16 CELL (4x4) PARABOLIC LOUVER

 

STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE

PHOTOMETRY

 

LER = FP - 42.0

IW - 57.6

BF - 90.3

 

 

 

 

 

 

 

 

 

MODEL NO. VRA2G16LS26U Comparative yearly lighting energy cost per 1000 lumens = $5.71

 

 

 

 

 

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

 

 

RF

 

 

20

 

 

 

 

 

20

 

 

 

 

 

20

 

 

 

 

RC

 

 

80

 

 

 

 

 

50

 

 

 

 

 

30

 

 

 

 

RW

 

70

50

 

30

 

50

 

30

 

10

 

 

50

30

10

 

 

 

1

 

58

57

 

55

 

53

 

52

 

51

 

 

51

51

50

 

 

ratio

2

 

55

52

 

49

 

49

 

47

 

46

 

 

48

46

45

 

 

3

 

51

47

 

44

 

45

 

43

 

41

 

 

44

42

40

 

 

 

 

 

 

 

 

 

 

 

 

cavity

4

 

48

44

 

40

 

42

 

39

 

37

 

 

41

38

36

 

 

5

 

45

40

 

37

 

39

 

36

 

33

 

 

38

35

33

 

 

room

6

 

42

37

 

33

 

36

 

33

 

30

 

 

35

32

30

 

 

7

 

40

34

 

31

 

33

 

30

 

28

 

 

32

30

28

 

 

 

8

 

37

32

 

28

 

31

 

28

 

25

 

 

30

27

25

 

 

 

9

 

35

29

 

26

 

29

 

26

 

23

 

 

28

25

23

 

 

 

10

 

33

27

 

24

 

27

 

24

 

22

 

 

26

24

22

 

 

visual comfort probability

(rated lumens per lamp 3150.)

 

 

 

 

 

 

 

 

 

room size

 

 

 

 

 

ceiling height

 

 

 

 

 

ceiling height

 

 

 

 

W

 

 

L

 

 

 

8.5

10.0

13.0

16.0

 

 

 

8.5

10.0

13.0

 

16.0

 

20

 

 

20

 

 

 

95

93

90

82

 

 

 

99

98

98

 

95

 

20

 

 

30

 

 

 

96

94

91

85

 

 

 

99

99

98

 

96

 

20

 

 

40

 

 

 

96

94

93

87

 

 

 

99

99

98

 

96

 

 

20

 

 

60

 

 

 

96

94

93

88

 

 

 

99

99

98

 

96

 

30

 

 

20

 

 

 

95

93

92

86

 

 

 

99

98

98

 

95

 

30

 

 

30

 

 

 

96

95

93

87

 

 

 

99

99

98

 

96

 

30

 

 

40

 

 

 

96

95

94

89

 

 

 

99

99

98

 

96

 

30

 

 

60

 

 

 

96

95

94

90

 

 

 

99

99

98

 

96

 

 

30

 

 

80

 

lengthwise

 

96

94

94

90

 

 

crosswise

99

99

98

 

96

 

40

 

 

40

 

 

96

95

94

90

 

 

99

99

98

 

96

 

40

 

 

20

 

 

 

95

94

92

86

 

 

 

99

99

98

 

96

 

40

 

 

30

 

luminaries

 

96

95

93

88

 

 

luminaries

99

99

98

 

96

 

40

 

 

60

 

 

96

94

94

91

 

 

99

99

98

 

96

 

40

 

 

80

 

 

 

96

94

94

91

 

 

 

99

99

98

 

96

 

 

40

 

 

100

 

 

 

96

94

94

91

 

 

 

99

99

98

 

97

 

60

 

 

30

 

 

 

96

95

93

88

 

 

 

99

99

98

 

96

 

60

 

 

40

 

 

 

96

94

94

90

 

 

 

99

99

98

 

96

 

60

 

 

60

 

 

 

96

95

94

91

 

 

 

99

99

98

 

97

 

 

 

 

 

 

 

 

 

 

 

60

 

 

80

 

 

 

96

95

94

91

 

 

 

99

99

98

 

97

 

 

60

 

 

100

 

 

 

96

95

94

91

 

 

 

99

99

98

 

97

 

100

 

 

40

 

 

 

96

94

94

90

 

 

 

99

99

98

 

97

 

100

 

 

60

 

 

 

96

95

94

91

 

 

 

99

99

98

 

97

 

100

 

 

80

 

 

 

96

95

94

91

 

 

 

99

99

98

 

97

 

 

100

 

 

100

 

 

 

96

95

94

91

 

 

 

99

99

99

 

97

ORDERING INFORMATION

Explanation of Catalog Number. Example: VRA2G16LS26U120SORF

VR

 

 

 

 

2

 

 

 

16

 

 

 

 

S

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BODY STYLE:

 

 

CEILING TYPE:

 

 

LOUVER

 

 

LAMP

 

 

A=Air Handling

 

 

G= Grid

 

 

FINISH*:

 

 

QUANTITY

 

 

S=Static

 

 

(lay-in T bar)

 

 

L=Low

 

 

 

 

 

 

 

 

F=Flanged

 

 

Iridescence

 

 

 

VR:

 

FIXTURE

(overlap)

NUMBER OF

Semi-specular

SINGLE “V”

 

 

4" Deep

WIDTH

Z spline and

CELLS:

(standard)

REFLECTOR

 

 

Pre-anodized

 

 

plaster

(4 rows of

P=Low

 

 

 

Aluminum

 

 

4 cells)

 

 

 

 

 

frame

Iridescence

 

 

 

Louver

 

 

 

 

 

 

 

 

 

T=Slot grid or

 

 

Specular

 

 

 

For Normal

 

 

 

 

 

 

 

VDT Use

two-directional

concealed

 

 

T (see options)

LAMP TYPE/

FIXTURE

LENGTH: 6"U Lamp

T8 OR T12

(Nominal 24")

VOLTAGE:

 

 

OPTIONS:

120 or 277

 

Add appropriate

 

 

 

 

suffix to catalog

 

 

 

 

no, ie: (GLR)

 

 

 

 

BALLAST TYPE:

 

1-2

Lamp Mag. T12

 

LE

<10THD

 

 

 

<20THD

1-2

Lamp Elec. T8

 

SO*

HI*

LOL T8 Dimming

 

PS

*Instant Start Standard

Other dimming options. Consult factory.

OPTIONS & ACCESSORIES

PLASTER FRAME: Catalog Number: PF22.

CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are

required between fixtures, Order Catalog Number: S2CTRIM (each joint).

SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ22 S2 SPLAY TRIM.

RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture

standard. SUFFIX: RF.

ELECTRICAL WIRING OPTIONS: Consult factory.

AIR CLOSURE STRIPS: SUFFIX ACS2 (factory installed).

DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio OA30-10.)

CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .57 with a spacing to mounting ratio of 1.2 perpendicular to the lamps. To meet IES RP1 preferred requirements for VDT areas the VCP (visual comfort proba- bility) shall not be less than 96 either crosswise or lengthwise and the maximum average brightness at 65°, 75° and 85° shall not exceed 293, 104, and 77 cande- las per square meter respectively in the 0°, 45°, and 90° horizontal planes. Candelas at Nadir (0°) not to exceed 1737.

SPECIFICATIONS (continued)

AIR HANDLING: (VRA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp com- partment through fixture body ends.

MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal).

FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi-specular anodized vertical grain aluminum reflec- tor sheet is standard.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier VRA2G16LS26U Page 2 of, Options & Accessories, Specifications, SPECIFICATIONS continued, Photometry, Type