| VR PARABOLIC VRA2G16LV2FT |
Page 2 of 2 | 2'x2' RECESSED FLUORESCENT, 4" DEEP, 16 CELL (4x4) PARABOLIC LOUVER |
| STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE |
PHOTOMETRY
| LER = FP - 39.0 | WATTS - 69.0 |
| BF - 0.82 |
|
|
|
|
|
| ||||||||||
MODEL NO. VRA2G16LV2FT Comparative yearly lighting energy cost per 1000 lumens = $6.15 |
|
|
| |||||||||||||||||
|
| coefficients of utilization — zonal cavity method | (effective floor cavity reflectance 0.20) |
| ||||||||||||||||
|
|
| ||||||||||||||||||
|
|
| RF |
|
| 20 |
|
|
|
|
| 20 |
|
|
|
|
| 20 |
| |
|
|
| RC |
|
| 80 |
|
|
|
|
| 50 |
|
|
|
|
| 30 |
| |
|
|
| RW |
| 70 | 50 |
|
| 30 |
| 50 | 30 |
| 10 |
| 50 |
| 30 | 10 | |
|
|
| 1 |
| 59 | 57 |
|
| 56 |
| 54 | 53 |
| 52 |
| 52 |
| 51 | 50 | |
|
| ratio | 2 |
| 55 | 52 |
|
| 50 |
| 50 | 48 |
| 46 |
| 48 |
| 46 | 45 | |
|
| 3 |
| 52 | 48 |
|
| 45 |
| 45 | 43 |
| 41 |
| 44 |
| 42 | 40 | ||
|
| cavity | 4 |
| 48 | 43 |
|
| 40 |
| 42 | 39 |
| 37 |
| 41 |
| 38 | 36 | |
|
| 5 |
| 45 | 39 |
|
| 36 |
| 38 | 35 |
| 32 |
| 37 |
| 34 | 32 | ||
|
| room | 6 |
| 42 | 36 |
|
| 32 |
| 35 | 31 |
| 29 |
| 34 |
| 31 | 29 | |
|
| 7 |
| 39 | 32 |
|
| 29 |
| 31 | 28 |
| 26 |
| 31 |
| 28 | 25 | ||
|
|
| 8 |
| 35 | 29 |
|
| 25 |
| 28 | 25 |
| 22 |
| 28 |
| 24 | 22 | |
|
|
| 9 |
| 32 | 26 |
|
| 22 |
| 25 | 22 |
| 19 |
| 25 |
| 21 | 19 | |
|
|
| 10 |
| 30 | 23 |
|
| 20 |
| 23 | 19 |
| 17 |
| 22 |
| 19 | 17 | |
|
| visual comfort probability | (rated lumens per lamp 3150.) |
|
|
|
|
|
| |||||||||||
|
|
| room size |
|
|
|
|
| ceiling height |
|
|
|
|
| ceiling height |
|
| |||
|
| W |
|
| L |
|
|
| 8.5 | 10.0 | 13.0 | 16.0 |
|
|
| 8.5 | 10.0 | 13.0 |
| 16.0 |
| 20 |
|
| 20 |
|
|
| 90 | 88 | 84 | 74 |
|
|
| 95 | 90 | 87 |
| 75 | |
| 20 |
|
| 30 |
|
|
| 91 | 89 | 86 | 77 |
|
|
| 95 | 92 | 90 |
| 79 | |
| 20 |
|
| 40 |
|
|
| 91 | 90 | 88 | 80 |
|
|
| 95 | 91 | 90 |
| 82 | |
|
| 20 |
|
| 60 |
|
|
| 91 | 91 | 89 | 82 |
|
|
| 96 | 91 | 90 |
| 82 |
| 30 |
|
| 20 |
|
|
| 90 | 88 | 87 | 78 |
|
|
| 95 | 91 | 90 |
| 78 | |
| 30 |
|
| 30 |
|
|
| 91 | 90 | 88 | 80 |
|
|
| 96 | 92 | 92 |
| 82 | |
| 30 |
|
| 40 |
|
|
| 91 | 91 | 90 | 82 |
|
|
| 96 | 92 | 92 |
| 84 | |
| 30 |
|
| 60 |
|
|
| 92 | 91 | 91 | 84 |
|
|
| 96 | 92 | 92 |
| 84 | |
|
| 30 |
|
| 80 |
| lengthwise |
| 92 | 91 | 91 | 84 |
|
| crosswise | 96 | 92 | 92 |
| 84 |
| 40 |
|
| 40 |
|
| 92 | 91 | 90 | 84 |
|
| 96 | 92 | 92 |
| 86 | |||
| 40 |
|
| 20 |
|
|
| 90 | 88 | 87 | 80 |
|
|
| 95 | 91 | 90 |
| 81 | |
| 40 |
|
| 30 |
| luminaries |
| 91 | 90 | 89 | 82 |
|
| luminaries | 96 | 92 | 92 |
| 84 | |
| 40 |
|
| 60 |
|
| 92 | 91 | 91 | 85 |
|
| 96 | 92 | 92 |
| 86 | |||
| 40 |
|
| 80 |
|
|
| 92 | 91 | 91 | 86 |
|
|
| 96 | 92 | 92 |
| 86 | |
|
| 40 |
|
| 100 |
|
|
| 92 | 91 | 91 | 86 |
|
|
| 96 | 92 | 92 |
| 86 |
| 60 |
|
| 30 |
|
|
| 92 | 90 | 89 | 82 |
|
|
| 96 | 92 | 92 |
| 84 | |
| 60 |
|
| 40 |
|
|
| 92 | 91 | 90 | 84 |
|
|
| 96 | 92 | 92 |
| 86 | |
| 60 |
|
| 60 |
|
|
| 92 | 91 | 91 | 86 |
|
|
| 96 | 92 | 92 |
| 86 | |
|
|
|
|
|
|
|
|
|
| |||||||||||
| 60 |
|
| 80 |
|
|
| 92 | 91 | 91 | 86 |
|
|
| 96 | 92 | 92 |
| 86 | |
|
| 60 |
|
| 100 |
|
|
| 92 | 91 | 91 | 86 |
|
|
| 96 | 92 | 92 |
| 86 |
| 100 |
|
| 40 |
|
|
| 92 | 91 | 90 | 84 |
|
|
| 96 | 92 | 92 |
| 86 | |
| 100 |
|
| 60 |
|
|
| 92 | 91 | 91 | 86 |
|
|
| 96 | 92 | 92 |
| 86 | |
| 100 |
|
| 80 |
|
|
| 92 | 91 | 91 | 86 |
|
|
| 96 | 92 | 92 |
| 86 | |
|
| 100 |
|
| 100 |
|
|
| 92 | 91 | 91 | 86 |
|
|
| 96 | 92 | 92 |
| 86 |
ORDERING INFORMATION
Explanation of Catalog Number. Example: VRA2G16LV2FT120SBGLR
VR |
|
|
|
|
| 2 |
|
|
|
| 16 |
|
|
|
| V |
| 2 |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| BODY | STYLE: |
|
| CEILING TYPE: |
|
|
| LOUVER |
|
|
| LAMP |
| |||||||
|
|
| A=Air Handling |
|
| G= Grid |
|
|
| FINISH*: |
|
|
| QUANTITY |
| |||||||||
|
|
| S=Static |
|
|
|
|
| L=Low |
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
| F=Flanged |
|
|
| Iridescence |
|
|
|
|
|
| |||||
VR: |
| FIXTURE | (overlap) | NUMBER OF |
| SINGLE “V” |
|
|
| |||||||||||||||
|
|
|
| |||||||||||||||||||||
4" Deep | WIDTH | Z spline and | CELLS: |
| (standard) | REFLECTOR |
|
|
| |||||||||||||||
|
|
|
| |||||||||||||||||||||
|
| plaster frame | (4 rows of | P=Low |
|
|
|
|
|
| ||||||||||||||
Aluminum |
|
| 4 cells) |
|
|
|
|
|
| |||||||||||||||
|
| T=Slot grid or |
| Iridescence |
|
|
|
|
|
| ||||||||||||||
Louver |
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
| Specular |
|
|
|
|
|
| |||||||||||||
For Normal |
|
|
|
|
|
|
|
|
|
|
|
VDT Use | concealed T | |
(see options) | ||
|
FT
|
|
| VOLTAGE: |
|
| OPTIONS: | ||
|
|
| 120 or 277 |
| Add appropriate | |||
|
|
|
|
|
| suffix to catalog | ||
|
|
|
|
|
| no, ie: (GLR) | ||
LAMP TYPE/ |
|
| ||||||
BALLAST TYPE: |
| |||||||
FIXTURE |
| |||||||
|
| <20THD | <10THD | |||||
LENGTH: | ||||||||
|
|
| ||||||
Twin Tube T5 |
| SB* | IB* | |||||
(Nominal 24") | (40 watt) |
| ||||||
|
|
| LOL TT5 Dimming |
| PB | – |
*Instant Start Standard
Other dimming options. Consult factory.
OPTIONS & ACCESSORIES
PLASTER FRAME: Catalog Number: PF22.
CONTINUOUS ROW INSTALLATION: For F type fixtures,
required between fixtures, Order Catalog Number: S2FCTRIM (each joint).
SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ22 S2 SPLAY TRIM.
RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture
standard. SUFFIX: RF.
ELECTRICAL WIRING OPTIONS: Consult factory.
AIR CLOSURE STRIPS: SUFFIX ACS2 (factory installed).
DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio
CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: In an installation of 2 lamp 40W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .57 with a spacing to mounting ratio of 1.8 perpendicular to the lamps. To meet IES RP1 preferred requirements for VDT areas the VCP (visual comfort proba- bility) shall not be less than 92 either crosswise or lengthwise and the maximum average brightness at 65°, 75° and 85° shall not exceed 267, 121 and 72 candelas per square meter respectively in the 0°, 45°, and 90° horizontal planes. Candelas at Nadir (0°) not to exceed 1224.
SPECIFICATIONS (continued)
AIR HANDLING: (VRA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp com- partment through fixture body ends.
MATERIALS: Chassis parts are
FINISH: Chassis
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and
Job Information |
| Type: |
|
|
|
Lightolier a Genlyte Thomas Company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902