| CLEANGUARD WET LOCATION WES SERIES 1X4 |
Page 2 of 2 | 1' x 4' RECESSED FLUORESCENT, FOR WET LOCATIONS, COVERED CEILING USE |
| 1 OR 2 LAMPS, T8 OR T12 |
PHOTOMETRY
MODEL NO. WES1GFSVA232 |
| LER = FL - 48.3 | IW - 80.0 | BF - 0.95 |
|
|
|
|
|
|
| ||||||||
| Comparative yearly lighting energy cost per 1000 lumens = $5.00 |
| |||||||||||||||||
|
| coefficients of utilization — zonal cavity method |
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
| RF |
|
| 20 |
|
|
|
| 20 |
|
|
|
|
|
| 20 |
|
|
|
| RC |
|
| 80 |
|
|
|
| 50 |
|
|
|
|
|
| 30 |
|
|
|
| RW | 70 |
| 50 |
| 30 |
| 50 | 30 |
| 10 |
|
| 50 | 30 | 10 | |
|
|
| 1 | 71 |
| 68 |
| 66 |
| 64 | 62 |
| 61 |
|
| 61 | 60 | 59 | |
|
| ratio | 2 | 65 |
| 61 |
| 57 |
| 57 | 55 |
| 52 |
|
| 55 | 53 | 51 | |
|
| 3 | 60 |
| 55 |
| 50 |
| 52 | 48 |
| 45 |
|
| 50 | 47 | 45 | ||
|
| cavity | 4 | 56 |
| 49 |
| 44 |
| 47 | 43 |
| 40 |
|
| 45 | 42 | 39 | |
|
| 5 | 51 |
| 44 |
| 39 |
| 42 | 38 |
| 35 |
|
| 41 | 37 | 34 | ||
|
| room | 6 | 48 |
| 40 |
| 35 |
| 38 | 34 |
| 31 |
|
| 37 | 33 | 30 | |
|
| 7 | 44 |
| 36 |
| 31 |
| 35 | 30 |
| 27 |
|
| 34 | 30 | 27 | ||
|
|
| 8 | 41 |
| 32 |
| 27 |
| 31 | 27 |
| 24 |
|
| 30 | 26 | 23 | |
|
|
| 9 | 37 |
| 29 |
| 24 |
| 28 | 24 |
| 21 |
|
| 27 | 23 | 20 | |
|
|
| 10 | 35 |
| 27 |
| 22 |
| 26 | 21 |
| 18 |
|
| 25 | 21 | 18 | |
|
| visual comfort probability (VCP) average 100 fc; reflectances 80/50/20 |
|
|
|
|
| ||||||||||||
|
|
| room size |
|
| ceiling height |
|
|
|
|
|
| ceiling height |
|
| ||||
|
| W |
| L |
| 8.5 | 10.0 | 13.0 | 16.0 |
|
|
|
| 8.5 | 10.0 | 13.0 | 16.0 |
| |
| 20 |
| 20 |
|
| 60 | 64 | 70 | 77 |
|
|
|
| 61 | 65 | 70 | 76 |
| |
| 20 |
| 30 |
|
| 51 | 56 | 61 | 67 |
|
|
|
| 54 | 57 | 62 | 68 |
| |
| 20 |
| 40 |
|
| 47 | 50 | 55 | 60 |
|
|
|
| 51 | 53 | 57 | 61 |
| |
|
| 20 |
| 60 |
|
| 43 | 46 | 59 | 54 |
|
|
|
| 49 | 50 | 52 | 56 |
|
| 30 |
| 20 |
|
| 62 | 66 | 70 | 75 |
|
|
|
| 63 | 67 | 70 | 75 |
| |
| 30 |
| 30 |
|
| 53 | 57 | 61 | 65 |
|
|
|
| 55 | 58 | 62 | 66 |
| |
| 30 |
| 40 |
|
| 48 | 51 | 54 | 58 |
|
|
|
| 51 | 53 | 56 | 60 |
| |
| 30 |
| 60 |
|
| 44 | 46 | 48 | 52 |
|
|
|
| 49 | 50 | 51 | 54 |
| |
|
| 30 |
| 80 |
| lengthwise | 42 | 44 | 44 | 48 |
|
| crosswise |
| 48 | 49 | 49 | 51 |
|
| 40 |
| 40 |
| 49 | 52 | 55 | 59 |
|
|
| 53 | 54 | 57 | 60 |
| |||
| 40 |
| 20 |
|
| 64 | 68 | 72 | 75 |
|
|
|
| 64 | 68 | 72 | 75 |
| |
| 40 |
| 30 |
| luminaries | 55 | 59 | 63 | 66 |
|
| luminaries |
| 57 | 60 | 63 | 66 |
| |
| 40 |
| 60 |
| 45 | 47 | 49 | 52 |
|
|
| 50 | 51 | 51 | 54 |
| |||
| 40 |
| 80 |
|
| 43 | 45 | 45 | 48 |
|
|
|
| 49 | 50 | 49 | 50 |
| |
|
| 40 |
| 100 |
|
| 42 | 43 | 43 | 45 |
|
|
|
| 50 | 49 | 48 | 49 |
|
| 60 |
| 30 |
|
| 57 | 60 | 64 | 67 |
|
|
|
| 58 | 61 | 64 | 67 |
| |
| 60 |
| 40 |
|
| 51 | 53 | 56 | 60 |
|
|
|
| 54 | 55 | 57 | 60 |
| |
| 60 |
| 60 |
|
| 46 | 48 | 49 | 52 |
|
|
|
| 50 | 51 | 51 | 54 |
| |
|
|
|
|
|
|
|
| ||||||||||||
| 60 |
| 80 |
|
| 44 | 45 | 45 | 48 |
|
|
|
| 49 | 50 | 49 | 50 |
| |
|
| 60 |
| 100 |
|
| 43 | 43 | 42 | 45 |
|
|
|
| 50 | 49 | 47 | 48 |
|
| 100 |
| 40 |
|
| 55 | 57 | 59 | 62 |
|
|
|
| 57 | 58 | 59 | 63 |
| |
| 100 |
| 60 |
|
| 50 | 51 | 52 | 55 |
|
|
|
| 53 | 54 | 53 | 56 |
| |
| 100 |
| 80 |
|
| 47 | 48 | 47 | 50 |
|
|
|
| 52 | 52 | 50 | 52 |
| |
|
| 100 |
| 100 |
|
| 46 | 46 | 44 | 46 |
|
|
|
| 52 | 51 | 49 | 49 |
|
ORDERING INFORMATION
Explanation of Catalog Number. Example: WES1GFSVA232120SOGLR
WE
CLEANGUARD
WET
LOCATION
S
STATIC
1
FIXTURE
WIDTH
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LENS FRAME: | ||
CEILING | TYPE: | FS= Flat steel | |||||
G= Grid |
| frame | |||||
| FA=Flat aluminum | ||||||
F=Flanged |
| frame | |||||
(overlap) | RA=Regressed alu | ||||||
| Z spline and |
| minum frame |
plaster frame
LENS/
SHIELDING
TYPE:
VA=Virgin acrylic (standard), see options and consult factory
LAMP
QUANTITY: 1 or 2 Lamps
LAMP/
FIXTURE LENGTH: 32=T8 34=T12
(Nominal 48")
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VOLTAGE: |
|
|
|
|
|
| OPTIONS: | ||||
120 or 277 |
|
|
|
|
| Add appropriate | |||||
|
|
|
|
|
|
|
| suffix to catalog | |||
|
|
|
|
|
|
|
|
| no., ie: (GLR) | ||
| BALLAST TYPE: |
|
|
|
|
| |||||
2 | Lamp Mag. T12 | LE |
|
|
|
|
| ||||
|
|
|
|
| |||||||
|
|
|
|
| <20THD | <10THD | |||||
2 | Lamp Elec. T8 | SO* |
| HI* | |||||||
LOL T8 Dimming | PS |
| – |
*Instant Start Standard
Other dimming options. Consult factory.
OPTIONS & ACCESSORIES
SPECIAL LENSES: Substitute VI for VA (standard) .125" nominal pattern 12 with 6.8 oz. average weight per square foot.
ACCESS PLATE: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP CSP.
CONTINUOUS ROW INSTALLATION: For F type fixtures,
are required between fixtures. Order Catalog Number: 1FC TRIM (each joint).
PLASTER FRAMES: F type fixtures do not include plaster frames. For individ- ual or continuous mounting, specify PF14 universal frame per fixture. ELECTRICAL/WIRING OPTIONS: Consult factory.
SEISMIC
FUSING: Internal
RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF.
DRYWALL KIT: Order Catalog Number: FK91X4. Request Folio
SPECIFICATIONS
PERFORMANCE: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .68. To prevent glare the VCP shall not be less than 46 either length-
wise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 682 footlamberts. To control veiling reflections, luminaire output in the
MATERIALS: Chassis parts are
aluminum frame, (RA) regressed
LABELS: I.B.E.W./UL and
Job Information |
| Type: |
Lightolier a Genlyte Thomas Company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902