Page 2 of 2 | High Performance, 2', Recessed Wallwasher/Accent Light |
| One Twin Tube T5 Lamp |
Photometry
Model No. WLRN124120SB LER = FP - 42.8 IW - 47 BF - 0.95
Comparative yearly lighting energy cost per 1000 lumens = $5.61
coefficients of utilization — zonal cavity method
| RF |
| 20 |
|
| 20 |
|
| 20 |
|
| RC |
| 80 |
|
| 50 |
|
| 30 |
|
| RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
ratio | 1 | 74 | 71 | 68 | 66 | 64 | 62 | 64 | 62 | 60 |
3 | 61 | 54 | 48 | 51 | 46 | 42 | 49 | 45 | 41 | |
| 2 | 67 | 61 | 57 | 58 | 54 | 51 | 55 | 52 | 49 |
cavity | 4 | 56 | 47 | 41 | 49 | 39 | 35 | 43 | 38 | 35 |
5 | 51 | 41 | 35 | 39 | 34 | 29 | 38 | 33 | 29 | |
room | 6 | 46 | 37 | 30 | 35 | 29 | 25 | 33 | 29 | 25 |
8 | 39 | 29 | 23 | 27 | 22 | 18 | 26 | 22 | 18 | |
| 7 | 42 | 32 | 26 | 31 | 25 | 21 | 30 | 25 | 21 |
| 9 | 35 | 26 | 19 | 24 | 19 | 15 | 24 | 19 | 15 |
| 10 | 33 | 23 | 17 | 22 | 17 | 13 | 21 | 16 | 13 |
FOOTCANDLES ON WALL Fixtures 3 feet from wall to outside trim on lamp side of fixture
Ceiling 8' 7' 6' 5' 4' 3' 2' 1'
Floor
|
|
| INDIVIDUAL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MULTIPLE UNITS |
|
|
|
|
|
|
|
|
|
|
|
|
| CONTINUOUS ROW |
|
|
|
| ||||||||||||||||||
| 0' | 1' | 2' | 3' | 4' | 5' | 6' | 7' | 8' |
|
|
|
|
|
|
|
| 04' |
|
|
|
|
|
|
|
|
|
|
|
| 6' |
|
|
|
|
|
|
| 0' | 1' | 2' | 3' | 4' | 5' | 6' | 7' | 8' |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 76 | 67 | 48 | 25 | 14 | 08 | 5 | 4 | 3 | 107 | 104 | 102 | 104 | 107 | 86 | 79 | 63 | 50 | 63 | 79 | 86 |
| 204 | 204 | 209 | 208 | 212 | 208 | 209 | 204 | 204 |
| |||||||||||||||||||||||
| 64 | 68 | 48 | 29 | 17 | 10 | 7 | 5 | 4 | 102 | 104 | 106 | 104 | 102 | 78 | 75 | 67 | 58 | 67 | 75 | 78 |
| 201 | 203 | 208 | 208 | 212 | 208 | 208 | 203 | 201 |
| |||||||||||||||||||||||
| 47 | 44 | 36 | 24 | 17 | 12 | 8 | 6 | 4 | 085 | 086 | 088 | 086 | 085 | 63 | 62 | 57 | 48 | 57 | 62 | 63 |
| 165 | 166 | 173 | 172 | 177 | 172 | 173 | 166 | 165 |
| |||||||||||||||||||||||
| 33 | 34 | 29 | 24 | 14 | 10 | 8 | 6 | 5 | 066 | 074 | 074 | 974 | 066 | 49 | 50 | 48 | 48 | 48 | 50 | 49 |
| 132 | 142 | 140 | 148 | 145 | 148 | 140 | 142 | 132 |
| |||||||||||||||||||||||
| 26 | 28 | 23 | 23 | 14 | 11 | 8 | 6 | 5 | 059 | 065 | 062 | 065 | 059 | 42 | 45 | 42 | 40 | 42 | 45 | 42 |
| 113 | 124 | 121 | 130 | 126 | 130 | 121 | 124 | 113 |
| |||||||||||||||||||||||
| 19 | 21 | 29 | 17 | 12 | 9 | 8 | 6 | 5 | 048 | 053 | 056 | 053 | 048 | 35 | 36 | 37 | 34 | 37 | 36 | 35 |
| 096 | 100 | 104 | 106 | 109 | 106 | 104 | 100 | 096 |
| |||||||||||||||||||||||
| 15 | 16 | 15 | 13 | 11 | 9 | 8 | 6 | 5 | 042 | 044 | 046 | 044 | 042 | 31 | 31 | 31 | 26 | 31 | 31 | 31 |
| 080 | 082 | 088 | 088 | 093 | 088 | 088 | 082 | 080 |
| |||||||||||||||||||||||
| 13 | 12 | 11 | 11 | 10 | 8 | 7 | 6 | 5 | 038 | 037 | 036 | 037 | 038 | 27 | 26 | 26 | 22 | 26 | 26 | 27 |
| 067 | 068 | 074 | 074 | 079 | 074 | 074 | 068 | 067 |
| |||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ordering Information
Explanation of Catalog Number. Example: WLRN124120SBGLR
WL
R
N
1
2
Recessed | Reflector: | Lamps | Length: | |
Low iridescent |
| N= Low iridescent |
| 2=24" |
specular |
| specular aluminum |
|
|
|
|
| ||
wallwash |
| standard |
|
|
Options/Accessories
Fusing: Internal
Lens: .187, pattern 19 lens. Catalog Number: WLRKIT CSP (to be field installed).
Radio Interference Filter: To order one RIF per fixture,Suffix: R.
To order one RIF per ballast, Suffix: B.
Electrical/Wiring Options: Consult factory.Fluorescent Emergency Lighting System:
tery pack with charger and inverter. Suffix: EM.
Drywall Frame: Catalog Number: WL2DF/UNV.
|
|
|
|
|
|
|
|
|
Watts: | Voltage: |
|
|
|
| Options: | ||
1=18 Watts | 120 or 277 |
|
|
| Add appropriate | |||
2=24 Watts |
|
|
|
| suffix to catalog | |||
| ||||||||
4=40 Watts |
|
|
|
|
| no, ie: (GLR) | ||
5=50 Watts |
| Ballast Type: | ||||||
6=55 Watts |
|
|
| <20THD <10THD |
1 Lamp Magnetic (TT5) | BX* | – |
(40 Watt) |
|
|
1 Lamp Electronic (TT5) | BA* | – |
(18 Watt) |
|
|
1 Lamp Electronic (TT5) | BB* | – |
(24 Watt) |
| IB* |
1 Lamp Electronic (TT5) | SB* | |
(40 Watt) |
|
|
1 Lamp Electronic (TT5) | BE* | BP |
(50 Watt) |
|
|
1 Lamp Electronic (TT5) | BF | |
(55 Watt) |
|
|
LOL (TT5) Dimming | PB** | – |
(40 Watt) |
|
|
*Instant Start Standard |
|
|
Specifications
Materials: Chassis parts are
Finish: Chassis
Lens: Virgin acrylic .187 pattern 19 with square based male conical prisms (rotates for easy lamp replacement).
Electrical: Rapid start HPF, thermally protected class “P” ballast (Biax type). If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
optional drywall frame WL2DF/UNV.
Job Information | Type: |
|
|
Lightolier a Genlyte Company | www.lightolier.com |
Technical Information: (978) | |
631 Airport Road, Fall River, MA 02720 • (508) | |
We reserve the right to change details of design, materials and finish. | |
© 2005 a Genlyte company | Section5/Folio |