Wal-LyterWLRN244120SB

 

Wal-LyterWLRN244120SB

Page 2 of 2

High Performance, 4', Recessed Wallwasher/Accent Light

 

Two Twin Tube T5 Lamps

Photometry

Model No. WLRN244120SB LER = FP - 47.5 IW - 85 BF - 0.95

Comparative yearly lighting energy cost per 1000 lumens = $5.05

coefficients of utilization — zonal cavity method

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

ratio

1

73

70

67

65

63

61

63

61

59

3

60

53

47

50

45

42

48

44

41

 

2

66

61

56

57

53

50

55

52

49

cavity

4

55

47

40

44

39

35

42

38

35

5

50

41

34

39

33

29

37

33

29

room

6

46

36

30

34

29

25

33

28

25

8

38

29

22

27

22

18

26

21

18

 

7

42

32

26

31

25

21

30

25

21

 

9

35

25

19

24

19

15

23

19

15

 

10

32

23

17

22

17

13

21

16

13

FOOTCANDLES ON WALL Fixtures 3 feet from wall to outside trim on lamp side of fixture

Ceiling 8' 7' 6' 5' 4' 3' 2' 1'

Floor

 

 

 

 

INDIVIDUAL WAL-LYTER

 

 

 

 

 

 

 

 

MULTIPLE UNITS

 

 

 

 

 

 

 

 

0'

1'

2'

3'

4'

5'

6'

7'

8'

 

 

 

 

0

 

 

 

6'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

111.

101.

75.5

47.8

28.3

18.1

13.2

10.4

0.87

 

124.

119.

104.

95.4

104.

119.

124.

 

 

 

 

113.

104.

81.7

55.7

35.5

23.5

16.6

12.5

09.8

 

130.

127.

117.

111.

117.

127.

130.

 

 

 

 

86.4

81.0

66.9

49.8

34.8

24.6

17.7

13.4

10.4

 

104.

106.

102.

100.

102.

106.

104.

 

 

 

 

62.5

59.1

51.4

41.6

31.9

24.3

18.4

13.9

16.7

 

81.1

83.5

83.2

83.2

83.2

83.4

81.1

 

 

 

 

50.5

48.6

42.9

35.6

28.7

22.6

18.0

14.3

11.1

 

68.8

71.3

71.6

71.3

71.6

71.3

68.8

 

 

 

 

39.7

38.5

34.9

30.0

25.1

20.6

16.9

14.1

11.4

 

56.8

59.2

60.0

59.9

60.0

59.2

56.8

 

 

 

 

31.1

30.3

28.1

25.0

21.7

18.5

15.7

13.4

11.1

 

47.0

48.8

49.7

50.0

49.7

48.8

47.0

 

 

 

 

24.2

23.6

22.5

20.8

18.7

16.5

14.6

12.8

11.0

 

38.8

40.2

41.1

41.5

41.1

40.2

38.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MULTIPLE UNITS

 

 

 

CONTINUOUS ROW

 

 

 

0Ceiling

8'

0'

1'

2'

3'

4'

5'

6'

7'

8'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8'

120.

111.

88.6

65.7

56.5

65.8

88.6

111.

120.

181.

182.

183.

183.

184.

183.

183.

182,

181.

7'

124.

117.

98.4

79.0

70.9

79.1

98.4

117.

124.

200.

201.

203.

203.

203.

203.

203.

201.

200.

6'

97.7

94.8

84.7

74.4

69.6

74.4

84.7

94.8

97.7

173.

175.

176.

177.

177.

177.

176.

175,

173.

5'

74.1

73.5

69.9

66.0

63.8

66.0

69.9

73.5

74.1

143.

146.

147.

148.

148.

148.

147.

146.

143.

4'

62.6

63.4

61.2

58.3

57.3

58.3

61.1

63.4

62.6

125.

128.

129.

130.

130.

130.

129.

128.

125.

3'

51.9

53.0

52.1

50.6

50.2

50.6

52.0

53.1

51.9

108.

110.

111.

112.

113.

112.

111.

110.

108.

2'

43.0

44.1

43.9

43.4

43.2

43.4

43.9

44.0

43.0

91.9

03.0

05.2

05.9

96.3

95.9

95.2

93.9

91.9

1'

35.7

36.6

37.0

37.2

37.2

37.2

37.0

36.6

35.7

78.7

80.3

81.4

82.1

82.5

82.0

81.4

80.3

78.7

Floor

Ordering Information

Explanation of Catalog Number. Example: WLRN244120SBGLR

WL

R

2

4

Wal-Lyter:

Recessed

Reflector:

Lamps

Length:

Low iridescent

 

N= Low iridescent

 

4=48"

specular

 

specular aluminum

 

 

 

 

 

wallwash

 

standard

 

 

 

 

K = Pattern 19 virgin

 

 

 

 

acrylic lens

 

 

 

 

installed at factory

 

 

Options/Accessories

Fusing: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing. Suffix: GMF.

Lens: .187, pattern 19 lens. Catalog Number: WLRKIT-4 CSP to be field installed.

Radio Interference Filter: To order one RIF per fixture, Suffix: R.

To order one RIF per ballast, Suffix: B.

Electrical/Wiring Options: Consult factory.

Fluorescent Emergency Lighting System: Factory-installed emergency power

battery pack with charger and inverter. Suffix: EM.

Drywall Frame: Catalog Number: WL4DF/UNV.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Watts:

Voltage:

 

 

 

 

Options:

1=18 Watts

120 or 277

 

 

 

Add appropriate

2=24 Watts

 

 

 

 

suffix to catalog

 

4=40 Watts

 

 

 

 

 

no, ie: (GLR)

5=50 Watts

 

Ballast Type:

6=55 Watts

 

 

 

<20THD <10THD

2 Lamp Magnetic (TT5)

BX*

(40 Watt)

 

 

2 Lamp Electronic (TT5)

BA*

(18 Watt)

 

 

2 Lamp Electronic (TT5)

BB*

(24 Watt)

 

IB*

2 Lamp Electronic (TT5)

SB*

(40 Watt)

 

 

2 Lamp Electronic (TT5)

BE*

BP

(50 Watt)

 

 

2 Lamp Electronic (TT5)

*

BF

(55 Watt)

 

 

LOL (TT5) Dimming

PB**

(40 Watt)

 

 

*Instant Start Standard

 

 

Specifications

Materials: Chassis parts are die-formed 20 gauge cold rolled steel with integral adjustable hanger clamp. Reflectors–low iridescent specular aluminum are standard.

Finish: Chassis exterior–phosphate undercoating, baked white acrylic enamel. Reflector–low iridescent specular is standard.

Lens: Virgin acrylic .187 pattern 19 with square based male conical prisms (rotates for easy lamp replacement).

Electrical: Rapid start HPF, thermally protected class “P” ballast (Biax type). If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

optional drywall frame WL4DF/UNV.

Job Information

Type:

 

 

Lightolier a Genlyte Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

© 2005 a Genlyte company

Section5/Folio K10-12 Rev. A
Page 2
Image 2
Lightolier WLRN244120SB Page 2 of, Two Twin Tube T5 Lamps, Photometry, Ordering Information, Options/Accessories, Type